FEDL9208-01
OKI Semiconductor
ML9208
AC Characteristics-1
(V
DD
= 5.0 V
±10%,
V
FL
= V
DD
–42 V, Ta = –40 to +85°C, unless otherwise specified)
Parameter
CP
Frequency
CP
Pulse Width
DA Setup Time
DA Hold Time
CS
Setup Time
CS
Hold Time
CS
Wait Time
Data Processing Time
RESET
Pulse Width
RESET
Time
DA Wait Time
All Output Slew Rate
V
DD
Rise Time
V
DD
Off Time
Symbol
f
C
t
CW
t
DS
t
DH
t
CSS
t
CSH
t
CSW
t
DOFF
t
WRES
Condition
—
—
—
—
—
R
1
= 3.3 kΩ, C
1
= 47 pF
—
R
1
= 3.3 kΩ, C
1
= 47 pF
When
RESET
signal is input from
microcontroller etc. externally
When
RESET
signal is input from
microcontroller etc. externally
R
2
= 1.0 kΩ, C
2
= 0.1
µF
t
RSOFF
t
R
t
F
t
PRZ
t
POF
C
l
= 100 pF
—
t
R
= 20 to 80%
t
F
= 80 to 20%
Min.
—
250
250
250
250
16
250
8
250
250
—
250
—
—
—
5.0
Max.
2.0
—
—
—
—
—
—
—
—
—
200
—
2.0
2.0
100
—
Unit
MHz
ns
ns
ns
ns
µs
ns
µs
ns
ns
µs
ns
µs
µs
µs
ms
t
RSON
When mounted in the unit
When mounted in the unit, V
DD
= 0.0 V
AC Characteristics-2
(V
DD
= 3.3 V
±10%,
V
FL
= V
DD
–42 V, Ta = –40 to +85°C, unless otherwise specified)
Parameter
CP
Frequency
CP
Pulse Width
DA Setup Time
DA Hold Time
CS
Setup Time
CS
Hold Time
CS
Wait Time
Data Processing Time
RESET
Pulse Width
RESET
Time
DA Wait Time
All Output Slew Rate
V
DD
Rise Time
V
DD
Off Time
Symbol
f
C
t
CW
t
DS
t
DH
t
CSS
t
CSH
t
CSW
t
DOFF
t
WRES
Condition
—
—
—
—
—
R
1
= 3.3 kΩ, C
1
= 39 pF
—
R
1
= 3.3 kΩ, C
1
= 39 pF
When
RESET
signal is input from
microcontroller etc. externally
When
RESET
signal is input from
microcontroller etc. externally
R
2
= 1.0 kΩ, C
2
= 0.1
µF
t
RSOFF
t
R
t
F
t
PRZ
t
POF
C
l
= 100 pF
—
t
R
= 20 to 80%
t
F
= 80 to 20%
Min.
—
250
250
250
250
16
250
8
250
250
—
250
—
—
—
5.0
Max.
2.0
—
—
—
—
—
—
—
—
—
200
—
2.0
2.0
100
—
Unit
MHz
ns
ns
ns
ns
µs
ns
µs
ns
ns
µs
ns
µs
µs
µs
ms
t
RSON
When mounted in the unit
When mounted in the unit, V
DD
= 0.0 V
9/33