ML87V2107  
RYABN Read value range: 0 to 1  
Reads luminance absolute noise mode switching signal of internal operation state.  
RYABN = YABN in case either the auto mode is not set (NRAUTO = 0) or the follow-up setting is not  
set in the auto mode (AYABN = 0).  
RCLM[4:0] Read value range: 0_0000 to 1_1111  
Reads chrominance noise upper limit level of internal operation state.  
RCLM[4:0] = YCM[4:0] in case either the auto mode is not set (NRAUTO = 0) or the follow-up is not  
set in the auto mode (ACLM[0] = 0).  
RYNROFF Read value range: 0 to 1  
Reads chrominance NR ON/OFF switching signal of internal operation state.  
In case the auto mode is not set (NRAUTO = 0): RCNROFF = NROFF  
RYNRM Read value range: 0 to 1  
Reads chrominance motion detection noise mode 0 switching signal of internal operation state.  
In case the auto mode is not set (NRAUTO = 0): RCNRM = CNRM  
RYABN Read value range: 0 to 1  
Reads chrominance absolute noise mode switching signal of internal operation state.  
RCABN = CABN in case either the auto mode is not set (NRAUTO = 0) or the follow-up is not set in the  
auto mode (ACABN = 0).  
RNR2OFF Read value range: 0 to 1  
Adaptive 2D noise reduction ON/OFF signal of internal operation status.  
If the auto mode is not set (NRAUTO = 0) or if A2OFF = 1 is not set in the auto mode, RNR2OFF =  
NR2OFF is set.  
RYMS[3:0] Read value range: 0_0000 to 1_1111  
Reads luminance motion compensation level of internal operation state.  
RYMS[4:0] = YMS[4:0] in case either the auto mode is not set (NRAUTO = 0) or the follow-up is not  
set in the auto mode (AYMS[0] = 0).  
RYMOF[3:1] Read value range: 000 to 111  
Reads luminance motion compensation On/Off switching signal of internal operation state  
RYMOF[*] = YMOFF[*] in case either the auto mode is not set (NRAUTO = 0) or the follow-up is not  
set in the auto mode (AYMOFF[*] = 0). (* is 1 to 3.)  