内容描述: [Fast Page DRAM, 16MX4, 25ns, CMOS, PDSO32, 0.400 INCH, 1.27 MM PITCH, PLASTIC, SOP-32]
分类和应用: 动态存储器光电二极管内存集成电路
文件页数/大小: 16 页 / 199 K
品牌: OKI [ OKI ELECTRONIC COMPONETS ]
 浏览型号MD51V64405E-50JA的Datasheet PDF文件第4页浏览型号MD51V64405E-50JA的Datasheet PDF文件第5页浏览型号MD51V64405E-50JA的Datasheet PDF文件第6页浏览型号MD51V64405E-50JA的Datasheet PDF文件第7页浏览型号MD51V64405E-50JA的Datasheet PDF文件第9页浏览型号MD51V64405E-50JA的Datasheet PDF文件第10页浏览型号MD51V64405E-50JA的Datasheet PDF文件第11页浏览型号MD51V64405E-50JA的Datasheet PDF文件第12页  
FEDD51V64405E-01  
OKI Semiconductor  
MD51V64405E  
Notes: 1. A start-up delay of 200µs is required after power-up, followed by a minimum of eight initialization  
cycles (RAS-only refresh or CAS before RAS refresh) before proper device operation is achieved.  
2. The AC characteristics assume tT = 2ns.  
3. VIH (Min.) and VIL (Max.) are reference levels for measuring input timing signals. Transition times (tT)  
are measured between VIH and VIL.  
4. This parameter is measured with a load circuit equivalent to 1 TTL load and 100pF.  
The output timing reference levels are VOH=2.0 and VOL=0.8V.  
5. Operation within the tRCD (Max.) limit ensures that tRAC (Max.) can be met.  
tRCD (Max.) is specified as a reference point only. If tRCD is greater than the specified tRCD (Max.) limit,  
then the access time is controlled by tCAC  
.
6. Operation within the tRAD (Max.) limit ensures that tRAC (Max.) can be met.  
RAD (Max.) is specified as a reference point only. If tRAD is greater than the specified tRAD (Max.) limit,  
then the access time is controlled by tAA  
t
.
7. tCEZ (Max.), tREZ (Max.), tWEZ (Max.), and tOEZ (Max.) define the time at which the output achieved the  
open circuit condition and are not referenced to output voltage levels.  
8. tCEZ, and tREZ must be satisfied for open circuit condition.  
9. tRCH or tRRH must be satisfied for a read cycle.  
10. tWCS, tCWD, tRWD, tAWD and tCPWD are not restrictive operating parameters. They are included in the data  
sheet as electrical characteristics only. If tWCS tWCS (Min.), then the cycle is an early write cycle and  
the data out will remain open circuit (high impedance) throughout the entire cycle. If tCWD tCWD  
(Min.), tRWD tRWD(Min.), tAWD tAWD (Min.) and tCPWD tCPWD (Min.), then the cycle is a read modify  
write cycle and data out will contain data read from the selected cell; if neither of the above sets of  
conditions is satisfied, then the condition of the data out (at access time) is indeterminate.  
11. These parameters are referenced to the CAS, leading edges in an early write cycle, and to the WE  
leading edge in an OE control write cycle, or a read modify write cycle.  