ODHKGL4155KD-06
KGL4155KD
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
VD1
VD2
VB1/VB2
VC1
Min
-0.3
-0.3
-1.0
-1.0
-0.3
-1.0
-
Max
4.0
Unit
Note
Supply Voltage
V
V
Supply Voltage of Output Stage
X-Point Control and Reference Voltage
Modulation Current Control Voltage
Modulation Shut Down Control Voltage
Bias Current Control Voltage
Input Amplitude
4.0
2.4
V
1.6
V
MSD
VC2
VD1+0.3
2.6
V
V
Vin
1.5
Vpp
°C
°C
AC coupled
Operating Temperature at Package Base
Storage Temperature
Ts
-10
-40
100
Tst
125
RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Min
3.07
3.07
0.6
Typ
Max
3.47
3.47
1.8
1.4
1.2
2.4
1.0
1.0
VD1
0.1
-
Unit
Note
Supply Voltage
VD1
3.3
V
V
Supply Voltage of Output Stage
X-Point Control Voltage
VD2
3.3
VB1
VB2 1)
1.2
V
X-Point Reference Voltage
1.0
1.2
V
Modulation Current Control Voltage
Bias Current Control Voltage
Single-ended Input Amplitude
Differential Input Amplitude
VC1
0
-
-
-
-
-
-
-
-
V
VC2
0
V
0.4
Vpp
Vpp
V
AC coupled
AC coupled
Vin
0.2
VD1-0.3
0
@Output Enable
@Output Disable
Modulation Shut Down Control Voltage
MSD 2)
V
Low Voltage of Bias Current Output
Operating Temperature at Package Base
Input Interface
VL(BIAS)
Ts
1.9
V
-40
95
°C
AC coupled (External blocking capacitor is required)
AC coupled using external bias tee 3)
Output Interface
1) VB2 can be open or biased by the external circuit. For VB2 opened, VB2 is biased at about 0.364 x VD1.
2) MSD can be open or biased by the external circuit. For MSD opened, MSD is biased at about VD1.
3) Refer to TYPICAL APPLICATION of page 6.
2/11