CD
18
PC Series
10 000 h at 85°C
· Long Life
· High Reliability
· High Currents for High Professional Applications
·
and High Power Inverter
CD
136
PK
105°C
longer
life
CD
139
BL
105°C
CD
135
BP
longer
life
CD
138
PC
highest
voltage
CD
137
PX
Item
Operating Temperature Range (°C)
Voltage Range (V)
Capacitance Range (µF)
Capacitance Tolerance
(20°C, 120Hz)
Leakage Current (µA)
Dissipation Factor (20°C, 120Hz)
Characteristics
-40 ~ +85
350 ~ 450
1 000 ~ 18 000
± 20%
After 5 minutes at 20°C application of rated voltage, leakage
current is not more than 0,01CV or 5mA, whichever is smaller
C: Nominal Capacitance (µF) V: Rated Voltage (V)
Less than 0,15
Useful Life
Lifetime
Leakage Current
Capacity Change
Dissipation Factor
Condition:
Applied Voltage
Applied Current
Applied Temperature
Failure Rate Level
10 000h
>100 000h
Load Life
5 000h
Endurance Test
5 000h
1 000h
Shelf Life
Not more than specified value
Within ± 30% of initial value
Not more than 300% of specified value
Not more than specified Not more than specified
value
value
Within ± 20% of initial
value
Not more than 200% of
specified value
Within ± 10% of initial
value
Not more than 130% of
specified value
Not more than specified
value
Within ± 20% of initial
value
Not more than 200% of
specified value
U
R
I
R
85°C
≤ 1% Failure Rate
U
R
1,4 x I
R
40°C
U
R
I
R
85°C
U
R
I
R
= 0
85°C
U
R
= 0
I
R
= 0
85°C
≤ 1% Failure Rate
guaranteed
Multiplier for Ripple Current
Frequency Coefficient
2.5
Lifetime Diagram
50Hz
0,70
120Hz
1,00
300Hz
1,10
1kHz
1,30
≥ 10kHz
1,40
Frequency
Coefficient
I
A
–––
2.0
CD
138
PC Series
I
R
1.5
1.0
0.5
X16
Lifetime
Multiplier
X8
X4
X2
X1
0.0
40
50
60
70
80
90
TA
(˚C)
I
A
= actual ripple current at 120Hz, I
R
= rated ripple current at 120Hz, 85°C
Multiplier of Useful Life as a function of ambient temperature and ripple current load
Direct Contact & Support: Jianghai Europe GmbH +49 (0)2151-652088-0 info@jianghai-europe.com www.jianghai-europe.com
v2006.2
7
Screw
After test:
U
R
to be applied
for 30min
>24h before
measurement