5962-9215901HZX 参数 Datasheet PDF下载

5962-9215901HZX图片预览
型号: 5962-9215901HZX
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module, 3 Output, 30W, Hybrid,]
分类和应用: 局域网
文件页数/大小: 6 页 / 59 K
品牌: INFINEON [ Infineon ]
 浏览型号5962-9215901HZX的Datasheet PDF文件第2页浏览型号5962-9215901HZX的Datasheet PDF文件第3页浏览型号5962-9215901HZX的Datasheet PDF文件第4页浏览型号5962-9215901HZX的Datasheet PDF文件第5页浏览型号5962-9215901HZX的Datasheet PDF文件第6页  
l
LAMBDA ADVANCED ANALOG INC.  
ATR2800T Series  
Hybrid - High Reliability  
High Power Triple Output DC/DC Converters  
DESCRIPTION  
and screening can be accommodated. Contact  
The ATR2800T Series of DC/DC converters provide  
30 watts of output power over the full military  
temperature range with no derating. These devices  
are pin compatible with the Lambda Advanced  
Analog ATO series converters but offer twice the  
maximum output power in a lower profile package.  
A custom CMOS ASIC pulse width modulator  
operating at a nominal switching frequency of  
550KHz combined with a unique magnetic feedback  
circuit reduces circuit complexity for enhanced  
reliability. These converters provide 500 volt input  
to output isolation and operate in highly efficient  
single forward mode.  
Lambda  
Advanced  
Analog  
with  
specific  
requirements.  
FEATURES  
n
n
n
n
n
n
n
n
n
n
30 Watt Output Power  
Flexible Output Loading  
-55 to +125°C Operation  
Pin Compatible With ATO  
0.410” Maximum Height  
16 to 40 Volt Input Range  
The advanced feedback design and high operating  
frequency provide an extremely wide bandwidth  
control loop with high gain and phase margin. This  
results in fast dynamic line and load response as  
well as superior audio rejection. The control loop is  
compensated to provide optimum performance over  
the full military temperature range and over the 16  
to 40 volt input voltage range.  
500 Volt Input to Output Isolation  
High Audio Rejection  
MIL-STD-704 Compatible  
Load Fault Protection – Short Circuit and  
Overload  
n
TTL Level Compatible Synchronization  
These converters are protected against both  
continuous output short circuits and output overload.  
Either load fault condition will result in operating in a  
low power dissipation foldback mode.  
The  
converters will shut down for approximately 15  
milliseconds, then attempt to restart. This cycle will  
continue indefinitely unless the load fault is  
corrected.  
Recovery to normal operation is  
automatic upon removal of the load fault.  
Manufactured in a facility fully qualified to MIL-PRF-  
38534, these converters are available in four  
screening grades to satisfy a wide range of  
requirements. The CH grade is fully compliant to  
the requirements of MIL-PRF-38534 for class H.  
The HB grade is processed and screened to the  
class H requirement, but may not necessarily meet  
all of the other MIL-PRF-38534 requirements, e.g.,  
element evaluation and Periodic Inspections (PI) not  
required. Both grades are tested to meet the  
complete group “A” test specification over the full  
military temperature range without output power  
deration. Two grades with more limited screening  
are also available for use in less demanding  
applications. Variations in electrical, mechanical