19-218/R6C-AL1M2VY/3T
Reliability Test Items And Conditions
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test
Hours/Cycles
Sample
Size
No.
1
Items
Test Condition
Ac/Re
0/1
Temp. : 260℃±5℃
Min. 5sec.
Reflow Soldering
6 Min.
22 PCS.
H : +100℃ 15min
∫ 5 min
L : -40℃ 15min
H : +100℃ 5min
∫ 10 sec
300 Cycles
2
Temperature Cycle
Thermal Shock
22 PCS.
0/1
300 Cycles
3
4
22 PCS.
22 PCS.
0/1
0/1
L : -10℃ 5min
High Temperature
Storage
Low Temperature
Storage
DC Operating Life
High Temperature /
High Humidity
1000 Hrs.
1000 Hrs.
Temp. : 100℃
Temp. : -40℃
5
6
7
22 PCS.
22 PCS.
22 PCS.
0/1
0/1
0/1
IF = 20 mA
1000 Hrs.
1000 Hrs.
85℃/ 85%RH
Everlight Electronics Co., Ltd.
Device No. : DSE-0001313
http://www.everlight.com
Prepared date: 27-Apr-2009
Rev.1
Page: 8 of 10
Prepared by: Ashley Kuo
Revision : 2
Release Date:2009-04-30 21:26:10.0
LifecyclePhase:
Expired Period: Forever