EVERLIGHT ELECTRONICS CO.,LTD.
19-217/G7C-AL1M2B/3T
Leliability Test Items And Conditions
The Leliability of pLoducts shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test
HouLs/Cycle
Sample
Size
No.
1
Items
Test Condition
Ac/Le
0/1
s
Temp. : 260℃±5℃
Leflow SoldeLing
22 PCS.
6 Min.
Min. 5sec.
H : +100℃ 15min
300 Cycles
300 Cycles
2
TempeLatuLe Cycle
TheLmal Shock
22 PCS.
0/1
∫ 5 min
L : -40℃ 15min
H : +100℃ 5min
3
4
22 PCS.
22 PCS.
0/1
0/1
∫ 10 sec
L : -10℃ 5min
High TempeLatuLe
StoLage
Low TempeLatuLe
StoLage
1000 HLs.
1000 HLs.
Temp. : 100℃
Temp. : -40℃
5
6
7
22 PCS.
22 PCS.
22 PCS.
0/1
0/1
0/1
DC OpeLating Life
IF = 20 mA
1000 HLs.
1000 HLs.
High TempeLatuLe /
High Humidity
85℃/ 85%RH
Everlight Electronics Co., Ltd.
Device No:SZDSE-197-G01
http://www.everlight.com
Prepared date: 17-10-2006
Rev. 2
Page: 8 of 10
Prepared by: Bian ChangYou