EVERLIGHT ELECTRONICS CO., LTD.
17-21/R7C-AN2Q1B/3T
Reliability Test Items And Conditions
The reliability of products shall be satisfied with items listed below.
Confidence level : 90 %
LTPD : 10 %
Test
Hours/Cycles
Sample
Size
No.
1
Items
Test Condition
Ac/Re
0/1
Temp. : 260℃±5℃
6 min.
Reflow Soldering
22 Pcs.
Min.5 sec.
H : +100
℃
15min.
5 min.
℃ 15min.
300 Cycles
2
Temperature Cycle
Thermal Shock
22 Pcs.
0/1
∫
L : -40
H : +100
℃
5min.
300 Cycles
3
4
22 Pcs.
22 Pcs.
0/1
0/1
∫
10 sec.
L : -10
℃
5min.
High Temperature
Storage
Low Temperature
Storage
1000 Hrs.
1000 Hrs.
Temp. : 100
Temp. : -40
= 20 mA
/ 85% R.H.
℃
℃
5
6
7
22 Pcs.
22 Pcs.
22 Pcs.
0/1
0/1
0/1
DC Operating Life
IF
1000 Hrs.
1000 Hrs.
High Temperature
/ High Humidity
85
℃
Everlight Electronics Co., Ltd.
Device No: SZDSE-171-R03
http://www.everlight.com
Prepared date: 25-Jan-2005
Rev.: 1
Page: 8 of 10
Prepared by: Huadong DEN