17-21/BHC-AN1P2/3T
Reliability Test Items And Conditions
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test
Sample
Size
No.
1
Items
Test Condition
Ac/Re
0/1
Hours/Cycles
Temp. : 260℃±5℃
Reflow Soldering
22 PCS.
6 Min.
Min. 5sec.
H : +100℃ 15min
300 Cycles
300 Cycles
2
Temperature Cycle
Thermal Shock
22 PCS.
0/1
∫ 5 min
L : -40℃ 15min
H : +100℃ 5min
3
4
22 PCS.
22 PCS.
0/1
0/1
∫ 10 sec
L : -10℃ 5min
High Temperature
Storage
1000 Hrs.
1000 Hrs.
Temp. : 100℃
Temp. : -40℃
Low Temperature
Storage
5
6
7
22 PCS.
22 PCS.
22 PCS.
0/1
0/1
0/1
DC Operating Life
IF = 20 mA
1000 Hrs.
1000 Hrs.
High Temperature /
High Humidity
85℃/ 85% RH
Everlight Electronics Co., Ltd.
Device No: DSE-000
http://www.everlight.com
Rev.1
Page: 8 of 10
Prepared date: 30-Jun.-2011
Prepared by:ZhouChen