15-21/GHC-R2S2/2T
Reliability Test Items And Conditions
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test
Sample
Ac/Re
No.
1
Items
Test Condition
Hours/Cycles Size
Temp. : 260℃±5℃
Reflow Soldering
22 Pcs. 0/1
6 Min.
5 sec.
H : +100℃ 15min
300 Cycles
2
Temperature Cycle
Thermal Shock
22 PCS. 0/1
∫ 5 min
L : -40℃ 15min
H : +100℃ 5min
300 Cycles
1000 Hrs.
3
4
22 PCS. 0/1
22 PCS. 0/1
∫ 10 sec
L : -10℃ 5min
High Temperature
Storage
Temp. : 100℃
Low Temperature
Storage
Temp. : -40℃
IF = 20 mA
5
6
7
22 PCS. 0/1
22 PCS. 0/1
22 PCS. 0/1
1000 Hrs.
1000 Hrs.
1000 Hrs.
DC Operating Life
High Temperature /
High Humidity
85℃/85% RH
Everlight Electronics Co., Ltd.
Device No:DSE-0003945
http://www.everlight.com
Prepared date: 22-July-2010
Rev
1
Page: 8 of 10
Prepared by:Yang yuanyuan