12-21UYC/S530-A3/TR8
Reliability Test Items And Conditions
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test
Hours/Cycles
Sample
Size
No.
1
Items
Test Condition
Ac/Re
0/1
Temp. : 260℃±5℃
Reflow Soldering
22 PCS.
6 Min.
Min. 5sec.
H : +100℃15min
∫ 5 min
L : -40℃15min
H : +100℃5min
∫ 10 sec
300 Cycles
2
Temperature Cycle
Thermal Shock
22 PCS.
0/1
300 Cycles
3
4
22 PCS.
22 PCS.
0/1
0/1
L : -10℃5min
High Temperature
Storage
Low Temperature
Storage
1000 Hrs.
1000 Hrs.
Temp. : 100℃
5
6
7
Temp. : -40℃
IF = 20 mA
22 PCS.
22 PCS.
22 PCS.
0/1
0/1
0/1
DC Operating Life
1000 Hrs.
1000 Hrs.
High Temperature /
High Humidity
85℃/ 85%RH
Everlight Electronics Co., Ltd.
Device No. : SZDSE-121-
http://www.everlight.com
Prepared date: 6-Apr-2009
Rev.1
Page: 7 of9