Integrated Power Functions
•
600V-20A IGBT inverter for three-phase DC/AC power conversion (Please refer to Figure 3)
Integrated Drive, Protection and System Control Functions
•
For inverter high-side IGBTs: Gate drive circuit, High voltage isolated high-speed level shifting
Control circuit under-voltage (UV) protection
Note) Available bootstrap circuit example is given in Figures 10 and 11.
•
For inverter low-side IGBTs: Gate drive circuit, Short circuit protection (SC)
Control supply circuit under-voltage (UV) protection
•
•
Fault signaling: Corresponding to a UV fault (Low-side supply)
Input interface: 3.3/5V CMOS/LSTTL compatible, Schmitt trigger input
Pin Configuration
Top View
13.7
(1) VCC(L)
(21) NU
(22) NV
(23) NW
(2) COM
(3) IN(UL)
(4) IN(VL)
(5) IN(WL)
(6) VFO
19.2
(7) CFOD
(8) CSC
(9) IN(UH)
(24)
U
Case Temperature (T )
C
(10) VCC(UH)
(11) VB(U)
(12) VS(U)
(13) IN(VH)
(14) VCC(VH)
(15) VB(V)
(16) VS(V)
(17) IN(WH)
(18) VCC(WH)
(19) VB(W)
Detecting Point
(25) V
(26) W
(27) P
DBC Substrate
(20) VS(W)
Figure 2.