Extended Mode Register Set (EMRS)  
The Extended Mode Register Set stores the data for enabling or disabling DLL and selecting output driver  
strength. The default value of the extended mode register is not defined, therefore must be written after power  
up for proper operation. The extended mode register is written by asserting low on CS#, RAS#, CAS#, and  
WE#. The state of A0, A2 ~ A5, A7 ~ A11and BA1 is written in the mode register in the same cycle as CS#,  
RAS#, CAS#, and WE# going low. The DDR SDRAM should be in all bank precharge with CKE already high  
prior to writing into the extended mode register. A1 and A6 are used for setting driver strength to normal, weak  
or matched impedance. Two clock cycles are required to complete the write operation in the extended mode  
register. The mode register contents can be changed using the same command and clock cycle requirements  
during operation as long as all banks are in the idle state. A0 is used for DLL enable or disable. "High" on BA0  
is used for EMRS. Refer to the table for specific codes.  
Extended Mode Resistor Bitmap  
BA1  
0
BA0  
1
A11  
A10  
A9  
A8  
A7  
A6  
DS1  
A5  
A4  
A3  
A2  
A1  
DS0  
A0  
DLL  
RFU must be set to “0”  
RFU must be set to “0”  
BA0 Mode  
A6 A1  
Drive Strength  
Full  
Strength  
100%  
60%  
Comment  
A0  
0
1
DLL  
0
0
1
1
0
1
0
0
1
MRS  
EMRS  
Enable  
Disable  
SSTL-2 weak  
RFU  
RFU Do not use  
1 Matched impedance 30%  
Output driver matches impedance  
Power up Sequence  
Power up must be performed in the following sequence.  
1) Apply power to VDD before or at the same time as VDDQ, VTT and VREF when all input signals are held  
"NOP" state and maintain CKE “LOW”.  
2) Start clock and maintain stable condition for minimum 200us.  
3) Issue a “NOP” command and keep CKE “HIGH”  
4) Issue a “Precharge All” command.  
5) Issue EMRS – enable DLL.  
6) Issue MRS – reset DLL. (An additional 200 clock cycles are required to lock the DLL).  
7) Precharge all banks of the device.  
8) Issue two or more Auto Refresh commands.  
9) Issue MRS – with A8 to low to initialize the mode register.  
8