 浏览型号EM6A9320BIB-5H的Datasheet PDF文件第5页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第6页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第7页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第8页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第10页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第11页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第12页浏览型号EM6A9320BIB-5H的Datasheet PDF文件第13页  
EM6A9320BIB  
EtronTech  
Test Mode Field (A8~A7)  
These two bits are used to enter the test mode and must be programmed to "00" in normal operation.  
Table 10. Test Mode  
A8  
0
A7  
0
Test Mode  
Normal mode  
DLL Reset  
1
0
X
1
Test mode  
(BA0, BA1)  
Table 11. MRS/EMRS  
BA1  
RFU  
RFU  
BA0  
0
A11 ~ A0  
MRS Cycle  
1
Extended Functions (EMRS)  
Extended Mode Register Set (EMRS)  
The Extended Mode Register Set stores the data for enabling or disabling DLL and selecting output driver  
strength. The default value of the extended mode register is not defined, therefore must be written after power up  
for proper operation. The extended mode register is written by asserting low onCS,RAS , CAS , and WE . (the  
device should have all banks idle with no bursts in progress prior to writing into the mode register, and CKE  
should be High) The state of A0 ~ A11 and BA1 are written in the mode register in the same cycle  
asCK ,RAS , CAS , and WE going low. The DDR SDRAM should be in all bank precharge with CKE already high  
prior to writing into the extended mode register. A1 is used for setting driver strength. Two clock cycles are  
required to complete the write operation in the extended mode register. The mode register contents can be  
changed using the same command and clock cycle requirements during operation as long as all banks are in the  
idle state. A0 is used for DLL enable or disable. "High" on BA0 is used for EMRS. Refer to the table for specific  
codes.  
Table 12. Extended Mode Register Bitmap  
BA1 BA0 A11 A10 A9  
A8  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0 Address Field  
0
1
RFU must be set to “0”  
DS DLL Extended Mode Register  
BA0  
0
Mode  
MRS  
A1  
0
Drive Strength  
Full  
A0  
DLL  
0
1
Enable  
Disable  
1
EMRS  
1
Reserved  
Etron Confidential  
9