欢迎访问ic37.com |
会员登录 免费注册
发布采购

EM63B165TS-7SG 参数 Datasheet PDF下载

EM63B165TS-7SG图片预览
型号: EM63B165TS-7SG
PDF下载: 下载PDF文件 查看货源
内容描述: [32M x 16 bit Synchronous DRAM (SDRAM)]
分类和应用: 动态存储器
文件页数/大小: 53 页 / 1489 K
品牌: ETRON [ ETRON TECHNOLOGY, INC. ]
 浏览型号EM63B165TS-7SG的Datasheet PDF文件第3页浏览型号EM63B165TS-7SG的Datasheet PDF文件第4页浏览型号EM63B165TS-7SG的Datasheet PDF文件第5页浏览型号EM63B165TS-7SG的Datasheet PDF文件第6页浏览型号EM63B165TS-7SG的Datasheet PDF文件第8页浏览型号EM63B165TS-7SG的Datasheet PDF文件第9页浏览型号EM63B165TS-7SG的Datasheet PDF文件第10页浏览型号EM63B165TS-7SG的Datasheet PDF文件第11页  
EM63B165TS  
EtronTech  
Commands  
1
BankActivate  
(RAS# = "L", CAS# = "H", WE# = "H", BAs = Bank, A0-A12 = Row Address)  
The BankActivate command activates the idle bank designated by the BA0, 1 signals. By latching  
the row address on A0 to A12 at the time of this command, the selected row access is initiated. The  
read or write operation in the same bank can occur after a time delay of tRCD(min.) from the time of  
bank activation. A subsequent BankActivate command to a different row in the same bank can only be  
issued after the previous active row has been precharged (refer to the following figure). The minimum  
time interval between successive BankActivate commands to the same bank is defined by tRC(min.).  
The SDRAM has four internal banks on the same chip and shares part of the internal circuitry to reduce  
chip area; therefore it restricts the back-to-back activation of the two banks. tRRD(min.) specifies the  
minimum time required between activating different banks. After this command is used, the Write  
command and the Block Write command perform the no mask write operation.  
T0  
T1  
T2  
T3  
Tn+3 Tn+4  
Tn+5  
Tn+6  
CLK  
Bank A  
Bank A  
Bank B  
Bank A  
ADDRESS  
Row Addr.  
Col Addr.  
Row Addr.  
Row Addr.  
RAS# - CAS# delay(tRCD  
)
RAS# - RAS# delay time(tRRD)  
Bank A  
Activate  
Bank B  
Activate  
Bank A  
Activate  
R/W A with  
AutoPrecharge  
NOP  
NOP  
NOP  
NOP  
COMMAND  
RAS# - Cycle time(tRC  
)
AutoPrecharge  
Begin  
Don’t Care  
Figure 3. BankActivate Command Cycle  
(Burst Length = n)  
2
BankPrecharge command  
(RAS# = "L", CAS# = "H", WE# = "L", BAs = Bank, A10 = "L", A0-A9, A11 and A12 = Don't care)  
The BankPrecharge command precharges the bank disignated by BA signal. The precharged  
bank is switched from the active state to the idle state. This command can be asserted anytime after  
tRAS(min.) is satisfied from the BankActivate command in the desired bank. The maximum time any  
bank can be active is specified by tRAS(max.). Therefore, the precharge function must be performed in  
any active bank within tRAS(max.). At the end of precharge, the precharged bank is still in the idle state  
and is ready to be activated again.  
3
4
PrechargeAll command  
(RAS# = "L", CAS# = "H", WE# = "L", BAs = Don’t care, A10 = "H", A0-A9, A11 and A12 = Don't care)  
The PrechargeAll command precharges all banks simultaneously and can be issued even if all  
banks are not in the active state. All banks are then switched to the idle state.  
Read command  
(RAS# = "H", CAS# = "L", WE# = "H", BAs = Bank, A10 = "L", A0-A9 = Column Address)  
The Read command is used to read a burst of data on consecutive clock cycles from an active row  
in an active bank. The bank must be active for at least tRCD(min.) before the Read command is issued.  
During read bursts, the valid data-out element from the starting column address will be available  
following the CAS latency after the issue of the Read command. Each subsequent data-out element  
will be valid by the next positive clock edge (refer to the following figure). The DQs go into  
high-impedance at the end of the burst unless other command is initiated. The burst length, burst  
sequence, and CAS latency are determined by the mode register, which is already programmed. A  
full-page burst will continue until terminated (at the end of the page it will wrap to column 0 and  
continue).  
Rev. 2.0  
7
Feb. /2016