78LXX  
Electrical Characteristics 78L05A  
Electrical characteristics at specified virtual junction temperature, VI= 10V, IO = 40mA (unless otherwise noted)  
Parameter  
Test Conditions*  
78L05A  
Units  
Min  
Typ  
Max  
Output voltage**  
4.8  
5
5
5.2  
25°C  
0°C to 125°C  
V
IO= 1mA to 40 mA,  
4.75  
5.25  
VI= 7V to 20V  
IO= 1mA to 70mA,  
VI= 7V to 20V  
VI= 8V to 20V  
VI= 8V to 18V, f= 120Hz  
IO= 1mA to 100mA  
IO= 1mA to 40mA  
f= 10Hz to 100 KHz  
4.75  
5
5.25  
150  
100  
Input regulation  
32  
26  
49  
15  
8
42  
1.7  
3.8  
mV  
25°C  
Ripple rejection  
41  
dB  
25°C  
25°C  
Output regulation  
60  
30  
mV  
Output noise voltage  
Dropout voltage  
Bias current  
µV  
V
25°C  
25°C  
25°C  
6
mA  
5.5  
1.5  
0.1  
125°C  
0°C to 125°C  
Bias current change  
VI= 8V to 20V  
IO= 1mA to 40mA  
Electrical Characteristics 78L06A  
Electrical characteristics at specified virtual junction temperature, VI= 11V, IO = 40mA (unless otherwise noted)  
Parameter  
Test Conditions*  
78L06A  
Typ  
Units  
Min  
Max  
Output voltage**  
5.75  
6
6.25  
25°C  
0°C to 125°C  
V
IO= 1mA to 40 mA,  
5.7  
6
6.3  
VI= 8V to 20V  
IO= 1mA to 70mA,  
VI= 8V to 20V  
VI= 9V to 20V  
VI= 9V to 19V, f= 120Hz  
IO= 1mA to 100mA  
IO= 1mA to 40mA  
f= 10Hz to 100 KHz  
5.7  
6
6.3  
175  
125  
Input regulation  
35  
29  
48  
16  
9
46  
1.7  
3.9  
mV  
25°C  
Ripple rejection  
40  
dB  
25°C  
25°C  
Output regulation  
80  
40  
mV  
Output noise voltage  
Dropout voltage  
Bias current  
µV  
V
mA  
25°C  
25°C  
25°C  
6
5.5  
1.5  
0.1  
125°C  
0°C to 125°C  
Bias current change  
VI= 9V to 20V  
IO= 1mA to 40mA  
*
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal  
effects must be taken into account separately. All characteristics are measured with a 0.33µF capacitor across the input and a 0.1µF  
capacitor across the output.  
** This specification applies only for dc power dissipation permitted by absolute maximum ratings.  
BEIJING ESTEK ELECTRONICS CO.,LTD  
3