General  
Absolute Maximum Ratings  
Safety  
The PKG 2000 I Series DC/DC power mod-  
ules are designed in accordance with EN 60  
950, Safety of information technology equipment  
including electrical business equipment and certi-  
fied by SEMKO.  
Characteristics  
min  
max  
Unit  
TC  
Case temperature @ max output power  
45  
+100  
°C  
TS  
VI  
Storage temperature  
Input voltage  
55  
+125  
+40  
°C  
0.5  
V dc  
The PKG power modules are recognized by  
UL and meet the applicable requirements in  
UL 1950 Safety of information technology equip-  
ment, the applicable Canadian safety require-  
ments and UL 1012 Standard for power sup-  
plies.  
Isolation voltage  
(input to output test voltage)  
Singel output  
dual output  
1,500  
1,000  
V
ISO  
V dc  
VRC  
Vadj  
Remote control voltage pin 1  
Output adjust voltage pin 10  
10  
10  
+10  
+10  
Vdc  
Vdc  
The DC/DC power module shall be installed  
in an end-use equipment and considerations  
should be given to measuring the case tem-  
perature to comply with TCmax when in  
operation. They are intended to be supplied  
by isolated secondary circuitry and shall be  
installed in compliance with the require-  
ments of the ultimate application. If connect-  
ed to a 24 V DC power system reinforced  
insulation must be provided in the power  
supply that isolates the input from the ac  
mains. The isolation in the DC/DC power  
module is an operational insulation in accord-  
ance with EN 60 950. One pole of the input  
and one pole of the output is to be grounded  
or both are to be kept floating.  
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes  
referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or  
Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified  
manner.  
max  
Input TC < TC  
Characteristics  
Input voltage range1)  
Conditions  
min  
typ  
max  
Unit  
V
I
18  
36  
V
V
Turn-off input voltage  
Turn-on input voltage  
(See Operating Information)  
(See Operating Information)  
16  
17  
V
V
I
off  
V
Ion  
Equivalent inrush  
current resistance  
rIrush  
10  
mW  
The terminal pins are only intended for  
connection to mating connectors of internal  
wiring inside the end-use equipment.  
CI  
Input capacitance  
Input idling power  
3.6  
1.0  
mF  
PIi  
IO=0,TC= –30...+90°C  
2.0  
W
The isolation voltage is a galvanic isolation  
and is verified in an electric strength test.  
Test voltage (VISO) between input and output  
and between case and output is  
V = 26 V, TC = +25 °C  
RC connected to pin 4  
I
Input stand-by  
current  
1.0  
PRC  
W
1,500 Vdc (duals = 1,000 Vdc) for 60 s.  
In production the test duration may be de-  
creased to 1 s.  
Environmental Characteristics  
The capacitor between input and output has a  
value of 4.7 nF (duals = 22 nF) and the leak-  
age current is less than 1mA @ 26 Vdc.  
Characteristics  
Test procedure & conditions  
Frequency  
Amplitude  
Acceleration  
Number of cycles  
10–500 Hz  
0.75 mm  
10 g  
Flammability ratings of the terminal support  
and internal plastic construction details  
meets UL 94V-0.  
Vibration  
IEC 68-2-6 Fc  
(Sinusoidal)  
10 in each axis  
Frequency  
10...500 Hz  
Acceleration  
Spectral density  
Duration  
Random  
IEC 68-2-34 Ed  
vibration  
0.5 g2/Hz  
10 min in 3 directions  
medium (IEC 62-2-36)  
Note:  
1) The input voltage range 19...36 V meets  
the requirements for Normal input voltage  
range in 24 V DC power systems, 20…30 V.  
At input voltages exceeding 36 V (abnormal  
voltage) the power loss will be higher than at  
normal input voltage and TC must be limited  
to max +90 °C. Absolute max continuous  
input voltage is 40 V dc. Output characteris-  
tics will be marginally affected at 18 V (see  
also Turn-off Input Voltage).  
Reproducibility  
Shock  
Peak acceleration  
Shock duration  
200 g  
3 ms  
IEC 68-2-27 Ea  
(Half sinus)  
Temperature  
IEC 68-2-14 Na  
change  
Temperature  
Number of cycles  
40°C to +125°C  
100  
Temperature  
Humidity  
Duration  
85°C  
85% RH  
1000 hours  
Accelerated  
damp heat  
IEC 68-2-3 Ca  
with bias  
Solder  
resistability  
Temperature, solder  
Duration  
260°C  
10… 13 s  
IEC 68-2-20 Tb 1A  
Water  
Isopropyl alcohol  
Terpens  
+55 5°C  
+35 5°C  
+35 5°C  
with rubbing  
Resistance to  
cleaning solvents  
IEC 68-2-45 XA  
Method 1  
Method  
EN/LZT 146 03 R1A (Replaces EN/LZT 137 R5) ©Ericsson Microelectronics AB, May 2000  