欢迎访问ic37.com |
会员登录 免费注册
发布采购

PKF4221ASI 参数 Datasheet PDF下载

PKF4221ASI图片预览
型号: PKF4221ASI
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module, 2 Output, 15W, Hybrid]
分类和应用: 输入元件输出元件
文件页数/大小: 8 页 / 252 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PKF4221ASI的Datasheet PDF文件第1页浏览型号PKF4221ASI的Datasheet PDF文件第2页浏览型号PKF4221ASI的Datasheet PDF文件第3页浏览型号PKF4221ASI的Datasheet PDF文件第4页浏览型号PKF4221ASI的Datasheet PDF文件第5页浏览型号PKF4221ASI的Datasheet PDF文件第7页浏览型号PKF4221ASI的Datasheet PDF文件第8页  
Radiated EMS (Electro-Magnetic Fields)  
Operating Information  
Radiated EMS is measured according to test methods in  
IEC Standard publ. 801-3. No deviation outside the VO  
tolerance band will occur under the following conditions:  
Fuse Considerations  
To prevent excessive current from flowing through the input  
supply line, in the case of a short-circuit across the converter  
input, an external fuse should be installed in the non-earthed  
input supply line. We recommend using a fuse rated at  
approximately 2 to 4 times the value calculated in the formula  
below:  
Frequency range  
0.01...200 MHz  
200...1,000 MHz  
1...12 GHz  
Voltage level  
3 Vrms/m  
3 Vrms/m  
10 Vrms/m  
PO  
max  
Iin  
=
max  
Conducted EMS  
(ηmin × V min  
)
I
Electro Magnetic Susceptibility is measured by injection of  
electrical disturbances on the input terminals. No deviation  
outside the VO tolerance band will occur under the following  
conditions:  
Refer to the fuse manufacturer for further information.  
Remote Control (RC)  
Frequency range  
30...300 MHz  
Voltage level  
1.0 Vrms  
Turn-on or turn-off can be realized by using the RC-pin. If pin  
11 is connected to pin 17 the power modules turns off. Normal  
operation is achieved if pin 11 is open (NC). To ensure safe  
turn-off the voltage difference between pin 11 and 17 shall be  
less than 1.0V. RC is an open collector compatible input. A  
sink capacity of 1mA is needed. (see fig. 1).  
The signal is amplitude modulated with 1 kHz/80% and  
applied in both differential and common mode.  
ESD  
Electro Static Discharge is tested according to IEC publ. 801-  
2. No destruction will occur if the following voltage levels are  
applied to any of the terminal pins:  
PKF 4221A  
Test  
Voltage level  
4 kV  
2 kV  
Air discharge  
Contact discharge  
EFT  
Electrical Fast Transients on the input terminals could affect  
the output voltage regulation causing functional errors on  
the Printed Board Assembly (PBA). The PKF power modules  
withstand EFT levels of 0.5 kV keeping VO within the  
tolerance band and  
Figure 1  
2.0 kV without destruction. Tested according to IEC publ.  
801-4.  
Turn-on/off Input Voltage  
The power module monitors the input voltage and will turn on  
and turn off at predetermined levels set by means of external  
resistors.  
Output Ripple & Noise (VOac)  
Output ripple is measured as the peak to peak voltage of the  
fundamental switching frequency.  
To increase VIon a resistor should be connected between pin  
11 and 17 (see fig. 2).  
The resistance is given by the following equation:  
For VI>34.5V,  
Rinnom=(2510-VI)/(VI-34.5) kΩ  
VI is the desired turn-on input voltage. The values are nominal  
and apply when the unadjusted module turns on at 34.5V.  
To decrease VIon a resistor should be connected between pin  
10 and 11 (see fig. 3). The resistance is given by the following  
equation:  
For 30.5<VI<34.5 V,  
Rinnom=55×(VI-30.5)/(34.5-VI) kΩ  
VI is the desired turn-on input voltage. The values are nominal  
and apply when the unadjusted module turns on at 34.5V.  
EN/LZT ꢀ46 040 RꢀA ©Ericsson Power Modules AB, October 2003  
6