Typical Characteristics
Efficiency(typ) @ TA = +25°C
Power derating
Output characteristic (typ)
[V]
[W]
18
[%]
7.4
86
84
7.3
7.2
7.1
7.0
6.9
6.8
15
12
9
82
36 V
53 V
75 V
80
6
36 V
53 V
75 V
78
3
0
76
0.0
0.4
0.8
1.2
1.6
2.0
2.4
2.8 [A]
[˚C]
0
0.6
1.2
1.8
2.4
3.0 [A]
-50 -40 -30
+80 +90 +100 +110 +120
Load Current
Load Current
Case Temperature
Turn-on/turn-off input voltage
Dynamic load response (typ) @ +25°C
[V]
Temperature coefficient
[V]
37
7.3
The output
voltage deviation
is determined
by the load
transient (dI/dt)
38
7.2
7.1
7.0
6.9
6.8
6.7
36
35
34
33
32
31
200 mV/div
Load change:
dI/dt≈4A/µs
Turn-on
Turn-off
VI = 53V
IOstep=
0.55-1.65-0.55A
[˚C]
-40
-20
0
20
40
60
80
100 [˚C]
-30 -14.3 1.2 16.8 32.5 48.1 63.7 79.3 95
Case Temperature
0.5 ms/div
Case Temperature
EMC Specifications
During EMC measurements the PKF power module is
measured directly.
External Filter (class B)
Required external input filter in order to meet class B in EN 55022,
CISPR 22 and FCC part 15J.
The fundamental switching frequency is 510 kHz 5%
at IO = 0.22-2.2A
Test Conditions: VI= 53 V, IO= 2.2A at room temperature
L1 = 884 µH
C1, C2 = 680 nF
C5, C6 = 6.8 nF
C5
L1
+
-
pin 18
pin 17
Supply
voltage
C1
C2
C6
(pulse PO473)
Conducted EMI (input teminals)
PKF 4117 A without filter.
PKF 4117 A with filter.
PKF 4117A SI Datasheet EN/LZT 146 041 R1A ©Ericsson Power Modules AB, December 2003
5