Safety  
The PKF 2000 I series DC/DC power modules are designed in  
accordance with EN 60 950, Safety of information technology  
equipment including electrical business equipment. SEMKO certificate  
no. 9738248.  
The PKF power modules are recognized by UL and meet the  
applicable requirements in UL 1950 Safety of information technology  
equipment, the applicable Canadian safety requirements and UL  
1012 Standard for power supplies.  
The DC/DC power module shall be installed in an end-use  
equipment and considerations should be given to measuring the  
case temperature to comply with TCmax when in operation.  
Abnormal component tests are conducted with the input  
protected by an external 3 A fuse. The need for repeating these  
tests in the end-use appliance shall be considered if installed in a  
circuit having higher rated devices.  
The isolation is an operational insulation in accordance with  
EN 60 950.  
The DC/DC power module is intended to be supplied by isolated  
secondary circuitry and shall be installed in compliance with the  
requirements of the ultimate application. One pole of the input  
and one pole of the output is to be grounded or both are to be  
kept floating.  
The terminal pins are only intended for connection to mating  
connectors of internal wiring inside the end-use equipment.  
These DC/DC power modules may be used in telephone  
equipment in accordance with paragraph 34 A.1 of UL 1459  
(Standard for Telephone Equipment, second edition).  
The galvanic isolation is verified in an electric strength test. Test  
voltage (VISO) between input and output is 1,500 Vdc for  
60 s. In production the test duration is decreased to 1 s.  
The capacitor between input and output has a value of 1 nF and  
the leakage current is less than 1µA @ 26 Vdc.  
The case is designed in non-conductive epoxy. Its flamma-bility  
rating meets UL 94V-0. The oxygen index is 34%.  
Electrical Data  
Fundamental circuit diagram, Single output  
17  
10  
1
2
Control  
11  
8
9
18  
7
EN/LZT 146 31 R1A (Replaces EN/LZT 137 21 R6) © Ericsson Microelectronics AB, June 2000  
5