PKE 4211 PI
TC = 0…+95°C, VI = 38 ...72V unless otherwise specified.
Output
Output 1
typ
Characteristics
Conditions
Unit
min
max
5.16
5.39
Output voltage initial
setting and accuracy
5.10
4.87
5.13
V
V
VOi
TC = +25°C, IO = 5.0 A, V = 50 V
I
Output adjust range1)
Long term drift
included
Output voltage
tolerance band
IO = 0.1…1.0 ×IOmax
5.03
5.29
5.45
V
V
VO
Idling voltage
Line regulation
Load regulation
IO = 25 mA
I
I
O = IO
max
VI = 38…72 V
60
60
mV
mV
O= 0.1…1.0 × IOmax, V = 50 V
I
Load transient
recovery time
ttr
50
ms
IO = 0.1… 1.0 × IOmax, V = 50 V
load step = 0.5 × IOmax
I
–410
mV
di
V
Load transient voltage
£0.1A/ms
tr
dt
270
15
mV
ms
tr
Ramp-up time
Start-up time
0.1…0.9 × VO
IO
=
0.1…1.0 × IOmax
From V connection
I
ts
30
ms
to VO = 0.9 × VOi
Output current
IO
0
5.0
A
POmax
Max output power2)
25
W
Current limiting
threshold
102
%
A
Ilim
Isc
TC <TCmax
Short circuit current1)
Output ripple
ac
IO = IOmax
20 Hz…5 MHz
60
90
mV
p-p
VO
p-p, V = 50 V
f = 100 Hz sine wave, 1V
Supply voltage
rejection (ac)
I
SVR
50
dB
(SVR = 20 log (1 V
p-p/VOp-p))
1) See Operating Information.
2) SeeTypical Characteristics, Power derating.
Miscellaneous
Characteristics
Conditions
O = IOmax, V = 50 V, TC = +25°C
typ
Unit
min
max
h
Efficiency
80
84
%
W
I
I
Pd
Power dissipation
IO = IOmax, V = 50 V, TC = +25°C
4.8
6.3
I
EN/LZT 146 26 R1A (Replaces EN/LZT 137 31 R1) © Ericsson Microelectronics AB, June 2000