Ericsson Internal
E
SEC/S Kevin Zhou
PRODUCT SPECIFICATION
2 (4)
Prepared (also subject responsible if other)
No.
1/1301-BMR662 Uen
2
Technical Specification
Approved
Checked
Date
Rev
Reference
EN/LZT 146 420 R3A March 2014
PKB 4000A series Direct Converters
Input 36-72 V, Output up to 30 A / 125 W
MICRF
2011-02-24
C
© Ericsson AB
Ordering Information
Product program
PKB 4910A
Ericsson Power Modules fulfills and will continuously fulfill
all its obligations under regulation (EC) No 1907/2006
concerning the registration, evaluation, authorization and
restriction of chemicals (REACH) as they enter into force
and is through product materials declarations preparing for
the obligations to communicate information on substances
in the products.
Output
3.3 V, 30 A / 99 W
5.0 V, 25 A / 125 W
PKB 4111A
Product number and Packaging
PKB 4XXXXA n1n2n3
n3
Options
Mounting
n1
n2
Quality Statement
ο
Remote Control logic
Lead length
The products are designed and manufactured in an
industrial environment where quality systems and methods
like ISO 9000, Six Sigma, and SPC are intensively in use to
boost the continuous improvements strategy. Infant
mortality or early failures in the products are screened out
and they are subjected to an ATE-based final test.
Conservative design rules, design reviews and product
qualifications, plus the high competence of an engaged
work force, contribute to the high quality of the products.
ο
ο
Options
n1
Description
PI
SI
Through hole *
Surface mount
n2
n3
Negative *
Positive
P
Warranty
5.30 mm *
3.69 mm
4.57 mm
Warranty period and conditions are defined in Ericsson
Power Modules General Terms and Conditions of Sale.
LA
LB
Example a through-hole mounted, negative logic, short pin
product would be PKB 4910A PILA.
Limitation of Liability
Ericsson Power Modules does not make any other
warranties, expressed or implied including any warranty of
merchantability or fitness for a particular purpose
(including, but not limited to, use in life support
applications, where malfunctions of product can cause
injury to a person’s health or life).
* Standard variant (i.e. no option selected).
General Information
Reliability
The failure rate (λ) and mean time between failures
(MTBF= 1/λ) is calculated at max output power and an
operating ambient temperature (TA) of +40°C. Ericsson
© Ericsson AB 2014
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to
calculate the mean steady-state failure rate and standard
deviation (σ).
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
Telcordia SR-332 Issue 2 also provides techniques to
estimate the upper confidence levels of failure rates based
on the mean and standard deviation.
Mean steady-state failure rate, λ
Std. deviation, σ
233 nFailures/h
34.6 nFailures/h
MTBF (mean value) for the PKB-A series = 4.3 Mh.
MTBF at 90% confidence level = 3.6 Mh
Compatibility with RoHS requirements
The products are compatible with the relevant clauses and
requirements of the RoHS directive 2002/95/EC and have a
maximum concentration value of 0.1% by weight in
homogeneous materials for lead, mercury, hexavalent
chromium, PBB and PBDE and of 0.01% by weight in
homogeneous materials for cadmium.
Exemptions in the RoHS directive utilized in Ericsson
Power Modules products are found in the Statement of
Compliance document.