Ericsson Internal
EJUNGYA
PRODUCT SPECIFICATION
1 (5)
Prepared (also subject responsible if other)
No.
3/1301-BMR 636 01/A4 Uen
8
Technical Specification
Approved
Checked
Date
Rev
Reference
EN/LZT 146 382 R1A June 2007
PKB 4717 PINB
DC/DC converters, Input 36-75 V, Output 10.5 A/75 W
SEC/D (Julia You)
ECHWANG 2007-6-18
A
© Ericsson Power Modules AB
EMC Specification
Conducted EMI measured according to EN55022, CISPR 22
and FCC part 15J (see test set-up). See Design Note 009 for
further information. The fundamental switching frequency is
200 kHz for PKB 4717 PINB @ VI = 53 V, max IO.
Conducted EMI Input terminal value (typ)
Test set-up
Layout recommendation
The radiated EMI performance of the DC/DC converter will
depend on the PCB layout and ground layer design.
It is also important to consider the stand-off of the DC/DC
converter.
EMI without filter
If a ground layer is used, it should be connected to the output
of the DC/DC converter and the equipment ground or
chassis.
External filter (class B)
Required external input filter in order to meet class B in
EN 55022, CISPR 22 and FCC part 15J.
A ground layer will increase the stray capacitance in the PCB
and improve the high frequency EMC performance.
Filter components:
C1,2,6 = 1 μF/100 V
Ceramic
Output ripple and noise
Output ripple and noise measured according to figure below.
See Design Note 022 for detailed information.
C3, 4 = 2.2 nF/1500 V
Ceramic
C5 = 100 μF/100 V
Electrolytic
L1,L2 = 1.47 mH
2.8 A, Common Mode
Output ripple and noise test setup
EMI with filter