PKB 4713 PINB  
Operating Information  
Input Voltage  
Current Limiting  
All PKB 4000 series DC/DC converters include current  
limiting circuitry that allows them to withstand  
continuous overloads or short circuit conditions on the  
output. The output voltage will decrease towards zero for  
output currents in excess of max output current (IOmax).  
The converter will resume normal operation after removal  
of the overload. The load distribution system should be  
designed to carry the maximum short circuit output  
current specified.  
The input voltage range 36...75Vdc meets the  
requirements of the European Telecom Standard ETS 300  
132-2 for normal input voltage range in -48V and -60V  
DC power systems, -40.5...-57.0V and -50.0...-72V  
respectively. At input voltages exceeding 75V, the power  
loss will be higher than at normal input voltage and TC  
must be limited to absolute max +110oC. The absolute  
maximum continuous input voltage is 80V DC.  
Over Voltage Protection (OVP)  
Remote ON/OFF (RC)  
The PKB 4000 series DC/DC converters have latching  
output overvoltage protection. In the event of an  
overvoltage condition, the converter will shut down. The  
converter can be restarted by cycling the input voltage.  
The PKB 4000 series DC/DC converters have two remote  
on/off options available. The standard converter is  
provided with "negative logic" remote on/off. The  
negative logic remote on/off turns the converter off during  
a logic high voltage on the on/off pin and on during a  
logic low state. The second option is "positive Logic"  
remote on/off which can be ordered by adding the suffix  
"P" to the end of the part number such as PKB 4613 PIP.  
"Positive logic" remote on/off turns the converter on  
during a logic high and off during a logic low state.  
Output Voltage Adjust (Trim)  
All PKB 4000 series DC/DC converters have an Output  
Voltage Adjust pin (Trim). This pin can be used to adjust  
the output voltage above or below VOi. When increasing  
the output voltage, the voltage at the output pins  
(including any remote sensing offset) must be kept below  
the overvoltage trip point. Also note that at elevated  
output voltages the maximum power rating of the  
module remains the same, and the output current  
capability will decrease correspondingly. These converters  
trim according to the industry standard method.  
Optional (P) Remote Control  
Standard Remote Control  
RC (primary)  
Low  
Module  
ON  
RC (primary)  
Low  
Module  
OFF  
Open/High  
OFF  
Open/High  
ON  
The remote on/off is referenced to the primary side. A  
mechanical switch or an open collector transistor or FET  
must be provided between the -Vin and the remote on/off  
inputs to drive the RC inputs to turn the module on and  
off.  
In situations where it is desired to have the converter  
power up automatically without the need for control  
signals or a switch, the RC pin can be wired directly to the  
-Input circuit on the application board.  
To decrease VO connect RTRIM-DOWN from -SENSE to  
TRIM  
100  
- 2  
RTRIM-DOWN =5.11  
kW  
(
D%  
)
To increase VO connect RTRIM-UP from +SENSE to TRIM  
VO (100+D%) (100+2D%)  
RTRIM-UP =5.11  
kW  
(
)
1.225D%  
D%  
Output Voltage Trim for 12V  
Remote Sense  
The remote sense circuitry will compensate for moderate  
amounts of resistance in the distribution system and allow  
for voltage regulation at the load or other selected point.  
The remote sense lines will carry very little current and do  
not need a large cross sectional area. However, the sense  
lines on a pcb should be located close to a ground trace or  
ground plane. In a discrete wiring situation, the use of  
twisted pair wires or other technique to reduce noise  
susceptibility is highly recommended.  
1000000  
100000  
10000  
1000  
100  
D e c r e a s e  
I n c r e a s e  
10  
The converter will compensate for up to 0.5V voltage  
drop between the sense voltage and the voltage at the  
power module output pins. The output voltage and the  
remote sense voltage offset must be less than the  
minimum over voltage trip point.  
1
0
2
4
6
8
10 12 14 16 18 20  
D
C h a n g e I n O u t p u t V o l t a g e ( % )  
6