PKB 4713 PINB  
Circuit Configuration for Output Voltage  
Adjustment (Trim)  
Input and Output Impedence  
The impedence of both the power source and the load will  
interact with the impedence of the DC/DC converter. It is  
most important to have the ratio between L and C as low as  
possible, i.e. a low characteristic impedence, both at the  
input and output, as the conveters have a low energy  
storage capability. The PKB 4000 series DC/DC  
converters have been designed to be completely stable  
without the need for external capacitors on the input or the  
output circuits. The performance in some applications can  
be enhanced by the addition of external capacitance as  
described below. If the distribution of the input voltage  
source to the converter contains significant inductance, the  
addition of a 100uF capacitor across the input of the  
converter will help insure stability. This capacitor is not  
required when powering the converter from a low  
impedence source with a short, low inductance, input  
power lead.  
+VOUT  
+VOUT  
+SENSE  
+SENSE  
Load  
R
TRIM-DOWN  
Load  
TRIM  
-SENSE  
-VOUT  
TRIM  
-SENSE  
-VOUT  
RTRIM-UP  
TRIM DOWN  
TRIM UP  
Output Ripple & Noise (VOac  
)
Output ripple is measured as the peak to peak voltage  
from 0 to 20MHz which includes the noise voltage and  
the fundamental ripple.  
Over Temperature Protection (OTP)  
The PKB 4000 series DC/DC converters are protected  
from thermal overload by an internal over temperature  
shutdown circuit. When the Pcb temperature adjacent to  
the primary mosfet exceeds +120oC (+5oC, -5oC), the  
power module will automatically shut down. It will restart  
when the temperature drops to +100oC (+5oC, -5oC).  
Output Capacitance  
When powering loads with significant dynamic current  
requirements, the voltage regulation at the load can be  
improved by the addition of decoupling capacitance at  
the load. The most effective technique is to locate low  
ESR ceramic capacitors as close to the load as possible,  
using several capacitors to lower the effective ESR. These  
ceramic capacitors will handle short duration high  
frequency components of dynamic load changes. In  
addition, higher values of electrolytic capacitors should be  
used to handle the mid-frequency components. It is  
equally important to use good design practices when  
configuring the DC distribution system.  
Low resistance and low inductance Pcb (printed circuit  
board) layouts and cabling should be used. Remember  
that when using remote sensing, all the resistance,  
inductance, and capacitance of the distribution system is  
within the feedback loop of the converter. This can have  
an affect on the converter's compensation and the  
resulting stability and dynamic response performance.  
As a "rule of thumb", 100uF/A of output current can  
be used without any additional analysis. For example,  
with a 20A converter, values of decoupling capacitance  
up to 2000uF can be used without regard to stability.  
With larger values of capacitance, the load transient  
recovery time can exceed the specified value. As much  
of the capacitance as possible should be outside of the  
remote sensing loop and close to the load. The absolute  
maximum value of output capacitance is 10,000uF.  
For values larger than this, please contact your local  
Ericsson Power Modules representative.  
Paralleling for Redundancy  
The figure below illustrates how n + 1 redundancy can be  
achieved. The customer provided diodes on the converter  
outputs allow a failed converter to remove itself from the  
shared group without pulling down the common output  
bus. This configuration can be extended to additional  
numbers of converters. Based on the desired circuit, the  
converters can be controlled individually or in groups by  
means of signals to the primary Remote On/Off inputs.  
EN/LZT 108 6071 P1D ©Ericsson Inc., Power Modules , February 2003  