欢迎访问ic37.com |
会员登录 免费注册
发布采购

PKB4810PIPNBMLB 参数 Datasheet PDF下载

PKB4810PIPNBMLB图片预览
型号: PKB4810PIPNBMLB
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module, 1 Output, 82.5W, Hybrid, ROHS COMPLIANT, PACKAGE-8]
分类和应用: 输入元件
文件页数/大小: 42 页 / 2514 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第2页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第3页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第4页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第5页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第7页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第8页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第9页浏览型号PKB4810PIPNBMLB的Datasheet PDF文件第10页  
Safety Specification  
General informationꢀ  
Isolated DC/DC convertersꢀ  
Ericsson Power Modules DC/DC converters and DC/DC regulators  
are designed in accordance with safety standards  
IEC/EN/UL 60 950, Safety of Information Technology Equipment.  
It is recommended that a fast blow fuse with a rating  
twice the maximum input current per selected product  
be used at the input of each DC/DC converterIf an input filter is  
used in the circuit the fuse should be placed in front of the input  
filterꢀ  
IEC/EN/UL60950 contains requirements to prevent injury or  
damage due to the following hazards:  
In the rare event of a component problem in the input filter or in the  
DC/DC converter that imposes a short circuit on the input source,  
this fuse will provide the following functions:  
Electrical shock  
Energy hazards  
Fire  
• Isolate the faulty DC/DC converter from the input power source  
so as not to affect the operation of other parts of the systemꢀ  
Mechanical and heat hazards  
Radiation hazards  
Chemical hazards  
• Protect the distribution wiring from excessive current and power  
loss thus preventing hazardous overheatingꢀ  
The galvanic isolation is verified in an electric strength testꢀ The test  
voltage (VISO) between input and output is 1500 Vdc or 2250 Vdc for  
60 seconds (refer to product specification)ꢀ Leakage current is less  
than 1µA at nominal input voltageꢀ  
On-board DC-DC converters are defined as component power  
suppliesꢀ As components they cannot fully comply with the  
provisions of any Safety requirements without “Conditions of  
Acceptability”ꢀ It is the responsibility of the installer to ensure that  
the final product housing these components complies with the  
requirements of all applicable Safety standards and Directives for  
the final productꢀ  
24 V dc systemsꢀ  
The input voltage to the DC/DC converter is SELV (Safety Extra Low  
Voltage) and the output remains SELV under normal and abnormal  
operating conditionsꢀ  
Component power supplies for general use should comply with  
the requirements in IEC60950, EN60950 and UL60950 “Safety of  
information technology equipment”ꢀ  
There are other more product related standards, eꢀgꢀ  
IEC61204-7 “Safety standard for power supplies",  
IEEE802ꢀ3af “Ethernet LAN/MAN Data terminal equipment  
power”, and ETS300132-2 “Power supply interface at the input to  
telecommunications equipment; part 2: DC”,  
48 and 60 V dc systemsꢀ  
If the input voltage to Ericsson Power Modules DC/DC converter  
is 75 V dc or less, then the output remains SELV (Safety Extra Low  
Voltage) under normal and abnormal operating conditionsꢀ  
but all of these standards are based on IEC/EN/UL60950 with  
regards to safetyꢀ  
Single fault testing in the input power supply circuit should be  
performed with the DC/DC converter connected to demonstrate  
that the input voltage does not exceed 75 V dcꢀ  
Ericsson Power Modules DC/DC converters and DC/DC regulators  
are UL 60 950 recognized and certified in accordance with EN 60  
950ꢀ  
If the input power source circuit is a DC power system, the source  
may be treated as a TNV2 circuit and testing has demonstrated  
compliance with SELV limits and isolation requirements equivalent  
to Basic Insulation in accordance with IEC/EN/UL 60 950ꢀ  
The flammability rating for all construction parts of the products  
meets UL 94V-0ꢀ  
The products should be installed in the end-use equipment, in  
accordance with the requirements of the ultimate applicationꢀ  
Normally the output of the DC/DC converter is considered as SELV  
(Safety Extra Low Voltage) and the input source must be isolated by  
minimum Double or Reinforced Insulation from the primary circuit  
(AC mains) in accordance with IEC/EN/UL 60 950ꢀ  
Non-isolated DC/DC regulatorsꢀ  
The input voltage to the DC/DC regulator is SELV (Safety Extra Low  
Voltage) and the output remains SELV under normal and abnormal  
operating conditionsꢀ  
It is recommended that a slow blow fuse with a rating  
twice the maximum input current per selected product  
be used at the input of each DC/DC regulatorꢀ  
EN/LZT 146 033 R9A ©Ericsson Power Modules, March 2007  
6
PKB 4000 Datasheet