Ericsson Internal
EZYPING
PRODUCT SPECIFICATION
1 (5)
Prepared (also subject responsible if other)
No.
2/1301-BMR 636 01/74 Uen
4
Technical Specification
Approved
Checked
Date
Rev
EN/LZT 146 3R9e4feRre5nAceAugust 2009
PKB 4000 series
SEC/D (Betty Wu)
ESECZHW
2009-2-9
B
© Ericsson AB
DC/DC converters, Input 36-75 V, Output 30 A/90 W
Absolute Maximum Ratings
Characteristics
min
-40
typ
max
+120
+125
+80
2250
100
6
Unit
°C
°C
V
Tref
TS
Operating Temperature (see Thermal Consideration section)
Storage temperature
-55
VI
Input voltage
-0.5
Viso
Vtr
Isolation voltage (input to output test voltage)
Input voltage transient (tp 100 ms)
Vdc
V
Positive logic option
Negative logic option
-0.5
-0.5
-0.5
V
Remote Control pin voltage
(see Operating Information section)
VRC
Vadj
40
V
Adjust pin voltage (see Operating Information section)
2xVoi
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Fundamental Circuit Diagram
Primary
Secondary
+ In
+ Out
+ Sense
Primary
Driver
Secondary
Driver
- Sense
- Out
Control and
Supervision
Vadj
Bias supply
Isolated
Feedback
RC
- In