General  
Absolute Maximum Ratings  
Stress in excess of Absolute Maximum  
Ratings may cause permanent damage.  
Absolute MaximumRatings, sometimes  
referred to as no destruction limits, are  
normally tested with one parameter at a time  
exceeding the limits of Output data or  
Electrical Characteristics. If exposed to stress  
above these limits, function and performance  
may degrade in an unspecified manner.  
Characteristics  
min  
max  
Unit  
TC  
Case temperature1)  
45  
+115  
°C  
TS  
Storage temperature  
55  
+125  
36  
°C  
V dc  
V dc  
Ws  
V
VI  
Input voltage  
0.5  
Isolation voltage (input to output test voltage)  
Transient input energy @ TA = +25°C  
Remote control voltage (pin 9)  
Output adjust voltage (pin 10)  
VISO  
500  
1.3  
0
VRC  
Vadj  
5
Safety  
0
VO  
V
The PKA 2000 I Series DC/DC power  
modules are designed in accordance with  
EN 60 950, Safety of information technology  
equipment including electrical business equipment  
and certified by SEMKO.  
1) Corresponding ambient temp. range (TA) at full output power is –45 to +85°C.  
The PKA power modules are recognized by  
UL and meet the applicable requirements in  
UL 1950 Safety of information technology equip-  
ment, the applicable Canadian safety require-  
ments and UL 1012 Standard for power sup-  
plies.  
Input TC < TC max  
Characteristics  
Conditions  
min  
typ  
max  
Unit  
TC < TCmax  
19  
32  
V
V
I
Input voltage range  
19  
13  
35  
18  
V
V
A
TC < + 95°C  
The DC/DC power module shall be installed  
in an end-use equipment and considerations  
should be given to measuring the case tem-  
perature to comply with TCmax when in  
operation. They are intended to be supplied  
by isolated secondary circuitry and shall be  
installed in compliance with the require-  
ments of the ultimate application. If con-  
nected to a 24 V DC power system reinforced  
insulation must be provided in the power  
supply that isolates the input from the ac  
mains. The isolation in the DC/DC power  
module is an operational insulation in accord-  
ance with EN 60 950. One pole of the input  
and one pole of the output is to be grounded  
or both are to be kept floating.  
V
Turn-off input voltage  
Inrush current2)  
(See Operating Information)  
I
off  
15  
5×10-4  
0.8  
IIrush  
IO = IOnom  
2
II  
A2s  
W
t
PIi  
Input idling power  
IO=0,TC= 0...+95°C  
Input transient peak  
current (transient  
immunity)  
P<1 kW, VC < 50 V,  
tr/td =10/1000 ms  
20  
A
2) PKA 2411 PIL = 30 A, 2×10-3 A2  
*) PKA 2432 PIL = 30 A, 5×10-3 A2  
s
s
The terminal pins are only intended for con-  
nection to mating connectors of internal  
wiring inside the end-use equipment.  
Environmental Characteristics  
The isolation voltage is a galvanic isolation  
and is verified in an electric strength test.  
Test voltage (VISO) between input and output  
is 500 Vdc.  
Characteristics  
Test procedure & conditions  
Frequency  
Amplitude  
10–500 Hz  
0.75 mm  
Vibration  
The capacitor between input and output has a  
value of 10 nF and the leakage current is less  
than 1mA @ 26 Vdc.  
IEC 68-2-6 Fc  
(Sinusoidal)  
Acceleration  
Number of cycles  
10 g  
10 in each axis  
Peak acceleration  
Shock duration  
200 g  
3 ms  
Shock  
Flammability ratings of the terminal support  
and internal plastic construction details  
meets UL 94V-0.  
IEC 68-2-27 Ea  
(Half sinus)  
Peak acceleration  
Bump duration  
40 g  
6 ms  
Bump  
(Half sinus)  
IEC 68-2-29 Eb  
Number of bumps  
1000 in 6 directions  
Temperature  
Number of cycles  
–40°C to +125°C  
10  
Temperature  
change  
IEC 68-2-14 Na  
IEC 68-2-3 Ca  
Temperature  
Duration  
40°C  
56 days  
Damp heat  
Temperature  
Humidity  
Duration  
85°C  
85% RH  
500 hours  
Accelerated  
damp heat  
IEC 68-2-3 Ca  
with bias  
EN/LZT 146 09 R1A © Ericsson Microelectronics AB, June 2000  