PBL 388 12
Ref.
fig.
Parameter
Conditions
Min.
Typ.
Max.
Unit.
NDet leakage current (hold), INDet
3
VTxDetIn = VRef - 0.1 V,
-100
nA
V
CMP = VRef + 0.1 V,
VCMP = VRef - 0.1 V,
TxDetIn = VRef + 0.1 V
Tx mode = max Tx gain,
Rx mode = max Rx gain
N
Det swing relative to VRef , VNDet
3
-0.45
50
V
V
CMP (comparator) sensitivity,
transmit (Tx) mode to receive
(Rx) mode or vice versa
3
13
100
mV
CTR voltage for 25 dB dynamics, VCTR
CTR voltage for mute, ICTR
CTR voltage for disable, VCTR
3
3
3
VCMP = VRef ± 0.35 V, RCTR=100kΩ
VCMP = VRef ± 0.35 V
V+
V
µA
V
0.55
Notes:
VNDet - VRef
1. 20 •10log (
)
VTxDet - VTxDetO
VNDet = voltage at noise detector output
VRef = reference voltage (about 1.9 V) see figure 2.
VTxDet = Voltage at transmit detector output.
VTxDetO
=
voltage at transmit detector output at the point
when the voltage at the noise detector starts
moving when a signal at transmit channel input is
gradually increased (threshold, typical value 30 mV)
2. Depends on V+. Channels are tracking.
4