Ericsson Internal
E
SECSUND
PRODUCT SPECIFICATION
1 (17)
Prepared (also subject responsible if other)
No.
2/1301-BMR 457 Uen
5
Technical Specification
BMR457 series Fully regulated AdvCahneckceed d Bus Converters
Approved
Date
Rev
Reference
SEC/D (Julia You)
EZHIXZH
2012-08-24
C
1/28701-FGCL101 1835 revC August 2012
© Ericsson AB
Input 36-75 V, Output up to 25 A / 300 W
Absolute Maximum Ratings
Characteristics
min
-40
-55
typ
max
+125
+125
Unit
°C
TP1
TS
Operating Temperature (see Thermal Consideration section)
Storage temperature
°C
+80
+65*
VI
Input voltage
-0.5
V
Viso
Isolation voltage (input to output test voltage), see note 1
2250
Vdc
Input voltage transient according to ETSI EN 300 132-2 and Telcordia GR-1089-
CORE
+100
+80*
Vtr
V
Remote Control pin voltage
(see Operating Information section)
VRC
-0.3
-0.3
18
V
V
V Logic I/O SALERT, CTRL, SCL, SDA, SA0, SA1
3.6
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits in the Electrical Specification. If exposed to stress above these limits, function and performance
may degrade in an unspecified manner.
Note 1: Isolation voltage (input/output to base-plate) max 750 Vdc.
*) Apply for the narrow input version VI= 40-60 V.
Fundamental Circuit Diagram
+IN
+OUT
-OUT
-IN
Auxillary
Supply
Driver
Control
RC
RC isolation