Technical Specification  
BMR454 series Fully regulated Intermediate Bus Converters  
EN/LZT 146 404 R7A March 2013  
© Ericsson AB  
Input 36-75 V, Output up to 40 A / 240 W  
Functional Description  
TP1 = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1 = +25°C, VI= 53 V, max IO , unless otherwise specified under Conditions  
Configuration File: 190 10-CDA 102 1900/001 rev A  
Characteristics  
Conditions  
min  
typ  
max  
Unit  
PMBus monitoring accuracy  
VIN_READ  
Input voltage  
-3  
-1.0  
-6  
+0.4  
-0.3  
-1.0  
-
3
1.0  
6
%
%
%
A
VOUT_READ  
IOUT_READ  
IOUT_READ  
TEMP_READ  
Output voltage  
Output current  
Output current  
Temperature  
VI = 53 V  
VI = 53 V, 50-100% of max IO  
VI = 53 V, 10% of max IO  
-0.7  
-5  
0.7  
5
ºC  
-
Fault Protection Characteristics  
Factory default  
-
-3  
-
33  
-
-
3
-
V
%
V
Setpoint accuracy  
Input Under  
Voltage Lockout,  
UVLO  
Factory default  
1.8  
Hysteresis  
Configurable via PMBus of  
threshold range, Note 1  
0
-
-
V
Delay  
-
-
200  
0
-
-
μs  
V
Factory default  
VOUT_UV_FAULT_LIMIT  
(Output voltage)  
Over/Under Voltage  
Protection,  
Configurable via PMBus, Note 1  
Factory default  
0
-
-
16  
-
V
15.6  
-
V
VOUT_OV_FAULT_LIMIT  
OVP/UVP  
Configurable via PMBus, Note 1  
VOUT  
-
16  
-
V
μs  
%
fault response time  
Setpoint accuracy  
200  
Io  
-6  
6
Over Current  
Protection,  
OCP  
Factory default  
-
25  
-
IOUT_OC_FAULT_LIMIT  
A
Configurable via PMBus, Note 1  
0
-
-
100  
fault response time  
OTP_FAULT_LIMIT  
200  
125  
-
-
μs  
Factory default  
-
Configurable via PMBus, Note 1  
Factory default  
-50  
125  
Over Temperature  
Protection,  
OTP  
C  
μs  
10  
OTP hysteresis  
Configurable via PMBus, Note 1  
0
-
165  
-
fault response time  
200  
Logic Input/Output Characteristics  
Logic input low (VIL)  
-
-
-
0.8  
-
V
V
CTRL_CS, SA0, SA1, PG_SYNC,  
SCL, SDA,  
Logic input high (VIH)  
2.0  
CTRL_CS, PG_SYNC, SALERT,  
SCL, SDA  
IOL = 5 mA  
Logic output low (VOL  
)
-
-
-
0.4  
-
V
V
CTRL_CS, PG_SYNC, SALERT,  
SCL, SDA  
Logic output high (VOH  
)
2.8  
IOH = -5 mA  
Setup time, SMBus  
Hold time, SMBus  
Bus free time T(BUF)  
100  
300  
200  
-
-
-
ns  
ns  
us  
Note 2  
Note 1: See Operating Information section.  
Note 2: It is recommended that a PMBus master read back written data for verification i.e. do not rely on the ACK/NACK bit since this bit are as susceptible to errors as any other bit*. However,  
under very rare operating conditions, it is possible to get intermittent read back failures. It is therefore recommended to implement error handling in the master that also deals with those situations.