欢迎访问ic37.com |
会员登录 免费注册
发布采购

B25667C7376A375 参数 Datasheet PDF下载

B25667C7376A375图片预览
型号: B25667C7376A375
PDF下载: 下载PDF文件 查看货源
内容描述: PhaseCap高级电容器 [PhaseCap Premium capacitors]
分类和应用: 电容器
文件页数/大小: 10 页 / 151 K
品牌: EPCOS [ EPCOS ]
 浏览型号B25667C7376A375的Datasheet PDF文件第2页浏览型号B25667C7376A375的Datasheet PDF文件第3页浏览型号B25667C7376A375的Datasheet PDF文件第4页浏览型号B25667C7376A375的Datasheet PDF文件第5页浏览型号B25667C7376A375的Datasheet PDF文件第6页浏览型号B25667C7376A375的Datasheet PDF文件第8页浏览型号B25667C7376A375的Datasheet PDF文件第9页浏览型号B25667C7376A375的Datasheet PDF文件第10页  
Film Capacitors – Power Factor Correction  
PhaseCap Premium capacitors  
B25667C7376A375  
MKK800-D-7.5-01  
Cautions and warnings  
In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not  
be used at all.  
This applies also in cases of oil leakages.  
To ensure the full functionality of the overpressure disconnector, elastic elements must not be  
hindered and a minimum space of 12 mm has to be kept above each capacitor.  
Do not handle the capacitor before it is discharged.  
Resonance cases must be avoided by appropriate application design in any case.  
Handle capacitors carefully, because they may still be charged even after disconnection due to  
faulty discharging devices.  
Protect the capacitor properly against over current and short circuit.  
Failure to follow cautions may result, worst case, in premature failures, bursting and fire.  
Discharging  
Capacitors must be discharged to a maximum of 10% of rated voltage before they are switched in  
again. This prevents an electric impulse discharge in the application, influences the capacitor’s  
service life and protects against electric shock. The capacitor must be discharged to 75 V or less  
within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit  
between the power capacitor and the discharging device. PhaseCap-capacitors either have a pre-  
mounted ceramic discharge module inserted from above into the middle section of the terminal, or for  
high voltages/high loads a plastic discharge module mounted at one side of the terminal; alternatively  
discharge reactors are available from EPCOS. Discharge and short circuit capacitor before handling!  
Service life expectancy  
Electrical components do not have an unlimited service life expectancy; this applies to self-healing  
capacitors too. The maximum service life expectancy may vary depending on the application the  
capacitor is used in.  
Safety  
Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property  
damage may result from bursting of the capacitor or from expulsion of oil or melted material due to  
mechanical disruption of the capacitor.  
Ensure good, effective grounding for capacitor enclosures.  
Provide means of disconnecting and insulating a faulty component/bank.  
The terminals of capacitors, connected bus bars and cables as well as other devices may also be  
energized.  
Follow good engineering practice.  
Thermal load/over-temperature  
After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not  
exceeded at extreme service conditions.  
FILM PFC PM  
May 2011  
Please read Cautions and warnings and  
Page 7 of 10  
Important notes at the end of this document.