PDF下载: 下载PDF文件 查看货源
内容描述: 薄膜电容器用????电力电子电容器 [Film capacitors – Power Electronic Capacitors]
分类和应用: 电容器薄膜电容器电子
文件页数/大小: 8 页 / 216 K
品牌: EPCOS [ EPCOS ]
 浏览型号B25360A6336J040的Datasheet PDF文件第1页浏览型号B25360A6336J040的Datasheet PDF文件第2页浏览型号B25360A6336J040的Datasheet PDF文件第3页浏览型号B25360A6336J040的Datasheet PDF文件第4页浏览型号B25360A6336J040的Datasheet PDF文件第5页浏览型号B25360A6336J040的Datasheet PDF文件第7页浏览型号B25360A6336J040的Datasheet PDF文件第8页  
Film capacitors – Power Electronic Capacitors  
General purpose applications  
B2536*  
MKP AC HP  
Cautions and warnings  
In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at  
all. This applies also in cases of leakage.  
To ensure the full functionality of the overpressure disconnector, elastic elements must not be hindered and a  
minimum space of 12 mm has to be kept above each capacitor.  
Check tightness of the connections/terminals periodically.  
The energy stored in capacitors may be lethal. To prevent any chance of shock, discharge and short-circuit  
the capacitor before handling.  
Failure to follow cautions may result, worst case, in premature failures, bursting and fire.  
EPCOS AG is not responsible for any kind of possible damages to persons or things due to improper  
installation and application of capacitors for power electronics.  
Safety  
Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage  
may result from bursting of the capacitor or from expulsion of oil or melted material due to mechanical  
disruption of the capacitor.  
Ensure good, effective grounding for capacitor enclosures.  
Observe appropriate safety precautions during operation (self-recharging phenomena and the high energy  
contained in capacitors).  
Handle capacitors carefully, because they may still be charged even after disconnection.  
The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized.  
Follow good engineering practice.  
Thermal load  
After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at  
extreme service conditions.  
Mechanical protection  
The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are  
avoided.  
Storage and operating conditions  
Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali,  
salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals  
is required to avoid conductive path between phases and/or phases and ground.  
The maximum storage temperature is 85 °C.  
FILM P PM  
May 2012  
Please read Cautions and warnings and  
Page 6 of 8  
Important notes at the end of this document.