欢迎访问ic37.com |
会员登录 免费注册
发布采购

AKR0.400D40 参数 Datasheet PDF下载

AKR0.400D40图片预览
型号: AKR0.400D40
PDF下载: 下载PDF文件 查看货源
内容描述: 压力传感器系列AK2 [Pressure sensors AK2 series]
分类和应用: 传感器压力传感器
文件页数/大小: 7 页 / 132 K
品牌: EPCOS [ EPCOS ]
 浏览型号AKR0.400D40的Datasheet PDF文件第1页浏览型号AKR0.400D40的Datasheet PDF文件第2页浏览型号AKR0.400D40的Datasheet PDF文件第3页浏览型号AKR0.400D40的Datasheet PDF文件第4页浏览型号AKR0.400D40的Datasheet PDF文件第6页浏览型号AKR0.400D40的Datasheet PDF文件第7页  
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Symbols and terms  
1)  
Storage temperature range Tst  
A storage of the pressure sensor within the temperature range Tst,min up to Tst,max  
and without applied pressure and supply voltage will not affect the performance of the pressure sensor.  
2)  
Operating temperature range Ta  
An operation of the pressure sensor within the temperature range Ta,min up to Ta,max  
will not affect the performance of the pressure sensor.  
3)  
Rated pressure pr  
Within the rated pressure range 0 up to pr the signal output characteristic corresponds to this specification.  
4)  
5)  
Overpressure pOV  
Pressure cycles within the pressure range 0 up to pov will not affect the performance of the pressure sensor.  
Supply voltage VDD  
VDD,max is the maximum permissible supply voltage, which can be applied without damages.  
The output voltage Vout is ratiometric (Vout ~ VDD).  
6)  
7)  
8)  
Offset V0  
The offset V0 is the signal output Vout(p = 0) at zero pressure.  
Sensitivity S  
Within the pressure range 0 up to pr the output voltage is Vout(px) = V0 + S · px  
Nonlinearity L (including pressure hysteresis)  
The nonlinearity is the deviation of the real sensor characteristic Vout = f(p) from the ideal straight line.  
It can be approximated by a polynomial of second order, with the maximum at px = pr / 2 .  
The equation to calculate the nonlinearity is:  
Vout (px ) V0 px  
L =  
Vout (pr ) V0 pr  
9)  
Temperature hysteresis  
The temperature hysteresis is the change of offset, starting from the value at 25 °C after a temperature change  
and return to 25 °C. Determined during temperature cycles in operating temperature range (cycles with 1 K/min).  
(Full Scale): FS = VFS = S · pr  
10)  
11)  
12)  
Temperature coefficients of the bridge resistance αRS, βRS  
Bridge resistance at temperature Tx: RS(Tx) = RS(25 °C) · [ 1 + αRS · (Tx – 25 °C) + βRS · (Tx – 25 °C)2 ]  
Values are valid within the operating temperature range Ta,min up to Ta,max  
Out of the operating temperature range, the deviation may increase.  
Temperature coefficients of the sensitivity αS, βS  
Sensitivity at temperature Tx: S(Tx) = S(25 °C) · [ 1 + αS · (Tx – 25 °C) + βS · (Tx – 25 °C)2 ]  
Values are valid within the operating temperature range Ta,min up to Ta,max  
Out of the operating temperature range, the deviation may increase.  
Temperature coefficient of offset TCV0  
Offset at temperature Tx: V0(Tx) = V0(25 °C) + TCV0 · (Tx – 25 °C) · VDD  
Values are valid within the operating temperature range Ta,min up to Ta,max  
Out of the operating temperature range, the deviation may increase.  
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 5 of 7  
Important notes at the end of this document.