eorex
EM488M1644VTB
AC Operating Test Conditions
(VDD=3.3V 0.3V, TA=0°C ~70°C)
Item
Conditions
1.4V/1.4V
Output Reference Level
Output Load
See diagram as below
2.4V/0.4V
Input Signal Level
Transition Time of Input Signals
Input Reference Level
2ns
1.4V
AC Operating Test Characteristics
(VDD=3.3V 0.3V, TA=0°C ~70°C)
-7.5
-7
-6
Uni
Symbol
tCK
Parameter
Min. Max. Min. Max. Min. Max.
CL=3
CL=2
CL=3
CL=2
7.5
10
7
6
Clock Cycle Time
ns
10
10
5.4
6
5.4
6
5.4
6
tAC
Access Time form CLK
ns
tCH
tCL
CLK High Level Width
CLK Low Level Width
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2
ns
ns
CL=3
CL=2
CL=3
CL=2
tOH
Data-out Hold Time
ns
ns
2.5
6
2.5
6
2
6
Data-out High Impedance
(Note 5)
Time
tHZ
tLZ
tIH
tIS
Data-out Low Impedance Time
Input Hold Time
0
1
0
0
ns
ns
ns
0.8
1.5
0.8
1.5
Input Setup Time
1.5
* All voltages referenced to VSS.
Note 5: tHZ defines the time at which the output achieve the open circuit condition and is not referenced to
output voltage levels.
Dec. 2006
www.eorex.com
7/17