 浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第1页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第2页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第3页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第4页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第6页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第7页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第8页浏览型号EM428M1684RTA-5FE的Datasheet PDF文件第9页  
eorex  
EM42BM1684RTA  
Recommended DC Operating Conditions  
(VDD=2.5V 0.2V, TA=0°C ~ 70°C)  
Max.  
Symbol  
IDD1  
Parameter  
Test Conditions  
Units  
-5  
-6  
-75  
Burst length=2,  
tRCtRC(min.), IOL=0mA,  
One bank active  
(Note 1)  
110 100 100 mA  
Operating Current  
Precharge Standby Current in  
Power Down Mode  
IDD2P  
6
mA  
mA  
mA  
mA  
mA  
CKEVIL(max.), tCK=min  
CKEVIL(min.), tCK=min,  
/CSVIH(min.)  
Input signals are changed one time  
during 2 clks  
Precharge Standby Current in  
Non-power Down Mode  
IDD2N  
IDD3P  
IDD3N  
IDD4  
30  
15  
50  
Active Standby Current in  
Power Down Mode  
CKEVIL(max.), tCK=min  
CKEVIH(min.), tCK=min,  
/CSVIH(min.)  
Input signals are changed one time  
during 2 clks  
Active Standby Current in  
Non-power Down Mode  
READ  
130  
140  
200  
Operating Current (Burst  
(Note 2)  
Mode)  
t
CK tCK(min.), IOL=0mA,  
All banks active  
WRITE  
tRCtRFC (min.), All banks active  
(Note 3)  
IDD5  
IDD6  
mA  
mA  
Refresh Current  
Self Refresh Current  
5
CKE0.2V  
*All voltages referenced to VSS.  
Note 1: IDD1 depends on output loading and cycle rates.  
Specified values are obtained with the output open.  
Input signals are changed only one time during tCK (min.)  
Note 2: IDD4 depends on output loading and cycle rates.  
Specified values are obtained with the output open.  
Input signals are changed only one time during tCK (min.)  
Note 3: Min. of tRFC (Auto refresh Row Cycle Times) is shown at AC Characteristics.  
Recommended DC Operating Conditions (Continued)  
Symbol  
IIL  
Parameter  
Test Conditions  
Min.  
-5  
Max.  
Units  
uA  
0VIVDDQ, VDDQ=VDD  
All other pins not under test=0V  
Input Leakage Current  
+5  
+5  
IOL  
VOH  
VOL  
Output Leakage Current  
High Level Output Voltage  
Low Level Output Voltage  
-5  
uA  
V
0VOVDDQ, DOUT is disabled  
IO=-16.8mA  
VDDQ-0.373  
IO=+16.8mA  
0.373  
V
Jul. 2006  
www.eorex.com  
5/19