欢迎访问ic37.com |
会员登录 免费注册
发布采购

EN5330DI 参数 Datasheet PDF下载

EN5330DI图片预览
型号: EN5330DI
PDF下载: 下载PDF文件 查看货源
内容描述: 3A电压模式同步降压PWM DC -DC转换器 [3A Voltage Mode Synchronous Buck PWM DC-DC Converter]
分类和应用: 转换器
文件页数/大小: 11 页 / 473 K
品牌: ENPIRION [ ENPIRION, INC. ]
 浏览型号EN5330DI的Datasheet PDF文件第2页浏览型号EN5330DI的Datasheet PDF文件第3页浏览型号EN5330DI的Datasheet PDF文件第4页浏览型号EN5330DI的Datasheet PDF文件第5页浏览型号EN5330DI的Datasheet PDF文件第7页浏览型号EN5330DI的Datasheet PDF文件第8页浏览型号EN5330DI的Datasheet PDF文件第9页浏览型号EN5330DI的Datasheet PDF文件第10页  
Rev 1.0 – July 2005  
EN5330  
Pin Descriptions  
PIN  
NAME  
FUNCTION  
Output of the buffer leading to the error amplifier. Used for external modifications of  
the compensation network.  
1
COMP  
External feedback voltage input. Option for programming the output voltage with a  
2
3
XFB  
resistor divider on VOUT  
.
Remote voltage sense input. Connect this pin to the load voltage at the point to be  
regulated.  
VSENSE  
4
5
6
7
EAIN  
EAOUT  
ENABLE  
NC  
Input of the error amplifier for external modifications of the compensation network.  
Output of the error amplifier for external modifications of the compensation network.  
Enable input. An input high enables operation. An input low disables operation.  
NO CONNECT – Do not electrically connect this pin to PCB. See Note 5.  
Over-Voltage set-point input. When using an external voltage divider and the XFB pin. When  
VS0, VS1 and VS2 are left OPEN or pulled high, an additional voltage divider separate from  
the XFB pin is required to set the OVP set-point. In this mode, the OVP function is disabled if  
this voltage divider is not present.  
8
XOV  
9
10  
11  
PGND  
Power ground for the power stage circuits.  
12  
13  
14  
15  
16  
VOUT  
Voltage and power output.  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
VDRAIN  
PGND  
NC  
Test point between the power FETs and Inductor.  
Power ground for the power stage circuits.  
NO CONNECT – Do not electrically connect this pin to PCB. See Note 5.  
Power voltage input for the power stage circuits.  
PVIN  
27  
28  
29  
30  
31  
VS2  
ROCP  
VS1  
Voltage select line 2 input. See Table 1.  
Over-Current trip point adjust input. Used for adjusting the OCP trip point.  
Voltage select line 1 input. See Table 1.  
32  
33  
34  
AVIN  
AGND  
VS0  
Analog voltage input for the controller circuits.  
Analog ground for the controller circuits.  
Voltage select line 0 input. See Table 1.  
35  
36  
POK  
SS  
Power OK is an open drain transistor for power system state indication.  
Soft-Start node. A capacitor is connected between this pin and AGND.  
NOTES:  
5. This pin is used for engineering test purposes and reserved for future use. Solder, but do not electrically connect this pin to  
the PCB.  
www.enpirion.com  