欢迎访问ic37.com |
会员登录 免费注册
发布采购

EM91465A/B/C/D 参数 Datasheet PDF下载

EM91465A/B/C/D图片预览
型号: EM91465A/B/C/D
PDF下载: 下载PDF文件 查看货源
内容描述: 电话拨号器多功能拨号器\n [Telephone Dialer Multi-Function Dialer ]
分类和应用: 电话拨号器
文件页数/大小: 24 页 / 283 K
品牌: ELAN [ ELAN MICROELECTRONICS CORP ]
 浏览型号EM91465A/B/C/D的Datasheet PDF文件第5页浏览型号EM91465A/B/C/D的Datasheet PDF文件第6页浏览型号EM91465A/B/C/D的Datasheet PDF文件第7页浏览型号EM91465A/B/C/D的Datasheet PDF文件第8页浏览型号EM91465A/B/C/D的Datasheet PDF文件第10页浏览型号EM91465A/B/C/D的Datasheet PDF文件第11页浏览型号EM91465A/B/C/D的Datasheet PDF文件第12页浏览型号EM91465A/B/C/D的Datasheet PDF文件第13页  
EM91465 SERIES  
TONE/PULSE SWITCHABLE DIALER WITH LCD INTERFACE  
AND I.P.P. DETECT FUNCTION  
Keypad,SDO format and LCD display reference table:  
Keypad  
bit5  
bit4  
bit3  
bit2  
bit1  
bit0  
Display  
1
0
0
0
0
0
1
1
2
3
4
5
6
7
8
9
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
1
1
1
1
1
1
1
0
1
1
1
1
0
1
1
0
0
1
1
1
1
0
0
0
0
1
1
1
0
0
0
1
1
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
0
0
1
1
1
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
1
1
0
1
2
3
4
5
6
7
8
9
0
0
“*”/T  
#
P
*/”T”  
ST  
HOLD  
HF  
P
STORE  
HOLD  
Speaker  
A
A
F
clear all display  
Lock  
(Lock state)  
EM1~EM3  
RD  
MEMORY  
RD  
<Note> : The display of LCD panel “ST”,”Hold”,”HF”,”A”,”EM1~EM3”,”RD” is corresponding to EM32117  
with flag types.  
LOCK function  
The EM91465 series provide the LOCK function to inhibit toll dialing operation. Connecting a resistor on COL1  
pin to VSS can select different LOCK control method that is conventional key lock or password lock. Also the  
lock number that can be selected by connecting the resistors on COL2 or COL3 pin. After power on reset, the  
password is fixed to 000 automatically. The lock function is disabled when the password is equal to 000 .  
How to setup password  
• Set LOCK function to password control mode. (Connects a resistor on COL1 pin to VSS)  
• Off hook (or turn on HF function)  
• Push : # , # , ops1 , ops2 , ops3 , nps1 , nps2 , nps3 , # . If the ops1~ops3 are the same with current password,  
then nps1~nps3 will be stored in the dialer to replace current password. Otherwise, the current password can  
not be updated. All the numbers pressed in the password setup procedure can not be dialed out when current  
password is not equal to 000. If the current password are equal to 000, then only the first number “#” will be  
dialed out.  
Normal dialing :  
Set lock function to none lock mode (without resistor connected to COL1 pin) or set password equal to 000.  
In this case, the dialer is operated in normal mode and all functions work at unlimitation.  
* This specification are subject to be changed without notice.  
9.24.1998  
9