EM84520  
2-IN-ONE SCROLLING MOUSE CONTROLLER  
c). The counter accumulators are cleared after receiving any command except “Resend”.  
d). EM84520 receives a Resend command ( FE ), it transmit its last packet of data.  
e). In the stream mode “Resend” is received by EM84520 following a 3-byte data packet transmission  
to the system. EM84520 resend the 3-byte data packet prior to clearing the counter.  
f). A response is sent within 25 ms if  
a). The system requires a response  
b). An error is detected in the transmission  
g). If EM84520 is in the stream mode :  
a). The system disables EM84520 before issuing any command requiring a response.  
b). When a command requiring a response is issued by the system ,another command should not be issue  
until either the response is received or 25ms has passed.  
E). PS/2 Mouse Commands Description:  
There are 16 valid commands that transmits between the system and EM84520. The “FA” code is always the  
first response to any valid input received from the system other than a Set Wrap Mode or Resend command.  
The following table list the commands:  
Hex Code  
Command  
EM84520 echo code  
FF  
Reset  
FA,AA,00  
FE  
Resend  
XX,(XX,XX)  
F6  
Set Default  
FA  
F5  
Disable  
FA  
F4  
Enable  
FA  
F3,XX  
F2  
F0  
Set Sampling Rate  
Read Device Type  
Set Remote Mode  
Set Wrap Mode  
Reset Wrap Mode  
Read Data  
Set Stream Mode  
Status Request  
Set Resolution  
Set Auto-speed  
Reset Auto-speed  
FA,FA  
FA,00  
FA  
FA  
EE  
EC  
EB  
EA  
E9  
E8,XX  
E7  
FA  
FA,XX,XX,XX  
FA  
FA,XX,XX,XX  
FA,FA  
FA  
E6  
FA  
The following describes valid commands:  
a). Reset ( FF )  
EM84520 operation:  
a). Completion the reset.  
b). Transmitted FA, AA, 00 to the system.  
6.28.1999  
* This specification are subject to be changed without notice.  