欢迎访问ic37.com |
会员登录 免费注册
发布采购

EM84510BP 参数 Datasheet PDF下载

EM84510BP图片预览
型号: EM84510BP
PDF下载: 下载PDF文件 查看货源
内容描述: PS / 2滚轮鼠标控制器 [PS/2 SCROLLING MOUSE CONTROLLER]
分类和应用: 控制器
文件页数/大小: 19 页 / 110 K
品牌: ELAN [ ELAN MICROELECTRONICS CORP ]
 浏览型号EM84510BP的Datasheet PDF文件第4页浏览型号EM84510BP的Datasheet PDF文件第5页浏览型号EM84510BP的Datasheet PDF文件第6页浏览型号EM84510BP的Datasheet PDF文件第7页浏览型号EM84510BP的Datasheet PDF文件第9页浏览型号EM84510BP的Datasheet PDF文件第10页浏览型号EM84510BP的Datasheet PDF文件第11页浏览型号EM84510BP的Datasheet PDF文件第12页  
EM84510  
PS/2 SCROLLING MOUSE CONTROLLER  
Microsoft PS/2 scrolling mouse mode:  
(A) Entering procedure: Except in WRAP mode, while EM84510 received the following consecutive  
command.  
i. F3 C8  
ii. F3 64  
iii. F3 50  
---- set sampling rate 200/sec  
---- set sampling rate 100/sec  
---- set sampling rate 80/sec  
(B) Operating:  
a. All of the commands in legacy mode still be valid.  
b. The ID code of read device type command (F2) will changed from "00" to be "03".  
c. Data report will be four bytes format:  
Byte  
1
Bit  
0
1
2
3
Description  
Left button status; 1 = pressed  
Right button status; 1 = pressed  
Middle button status; 1 = pressed  
Reserve  
4
5
6
7
0-7  
0-7  
0-7  
X data sign; 1 = negative  
Y data sign; 1 = negative  
X data overflow; 1 = overflow  
Y data overflow; 1 = overflow  
X data ( D0 - D7 )  
2
3
4
Y data ( D0 - D7 )  
Z data ( D0 - D7 )  
(C) Exiting Microsoft scrolling mode:  
There are two ways to exit:  
a. Power off.  
b. Reset command (FF).  
Z-axis Input Function : The Z0-Z7 limit value is ±7  
(a) Photo couples input : Z-axis counter accumulates the Z1, Z2 phase changed by movement. This mode  
includes noise immunity.  
Z/1 : 1 dot per count.  
Z/4 : 4 dots per count. Counted by Z1=1, Z2=1 phase, the wheel should stay at Z1=0, Z2=0 phase.  
(b) Key-switches input : Pressing Z1, Z2 will start to fill the Z-axis counter with the value beginning at one.  
Toggling "M" key can increase the value any time by one. The limit value is ±7.  
The relationship between the value and the transmission rate as follows :  
5.30.2001  
* This specification are subject to be changed without notice.  
8