EM39LV800
8M Bits (512Kx16) Flash Memory
SPECIFICATION
Software Command Sequence
1st Bus
2nd Bus
3rd Bus
4th Bus
5th Bus
6th Bus
Command
Sequence
Write Cycle Write Cycle Write Cycle Write Cycle Write Cycle Write Cycle
Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
Word Program
Sector Erase
Block Erase
Chip Erase
5555H AAH 2AAAH 55H 5555H A0H
WA3
Data
4
4
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H
SAX
BAX
30H
50H
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H 5555H 10H
Software ID
Entry5,6
5555H AAH 2AAAH 55H 5555H 90H
Manufacture ID
Manufacture ID
Manufacture ID
Device ID
5555H AAH 2AAAH 55H 5555H 90H 0000H 0007F
5555H AAH 2AAAH 55H 5555H 90H 0003H 0007F
5555H AAH 2AAAH 55H 5555H 90H 0040H 0001F
5555H AAH 2AAAH 55H 5555H 90H 0001H 0020H
CFI Query Entry5 5555H AAH 2AAAH 55H 5555H 98H
Software ID
XXH
F0H
Exit7/CFI Exit
Software ID
5555H AAH 2AAAH 55H 5555H F0H
Exit7/CFI Exit
Notes:
1. Address format A14-A0 (Hex), Addresses A18-A15 can be VIL or VIH, but no other value, for the Command
sequence.
2. DQ15-DQ8 can be VIL or VIH, but no other value, for the Command sequence.
3. WA = Program word address.
4. SAX for Sector-Erase; uses A18-A11 address lines.
BAX for Block-Erase; uses A18-A15 address lines.
5. The device does not remain in Software Product ID mode if powered down.
6. Both Software ID Exit operations are equivalent.
7. Refer to Figure 9 for more information.
Table 3: Software Command Sequence
This specification is subject to change without further notice. (04.09.2004 V1.0)
Page 8 of 25