AT Commands (continued)  
I
[ Identify yourself ]  
the third byte in the message). As with the MA and  
MR monitoring modes, any RS232 activity (single  
character) will abort the monitoring.  
Issuing this command causes the chip to identify  
itself, by printing the startup product ID string (this is  
currently ‘ELM322 v2.0’). Software can use this to  
determine exactly which integrated circuit it is talking  
to, without resorting to resetting the entire IC.  
PD  
[ send Packed Data ]  
This option is for those who are building a computer  
interface and want the fastest data transfer rate  
possible while still operating at 9600 baud. When  
selected, responses from the vehicle will be  
formatted as an initial length byte followed by the  
actual response bytes from the vehicle, with no  
trailing carriage returns or linefeed characters. The  
data will not be altered in any way, except for the  
conversion to standard RS232 bytes.  
L0 and L1  
[ Linefeeds off (0) or on (1) ]  
Whether or not the ELM322 transmits a linefeed  
character after each carriage return character is  
controlled by this option. If an ATL1 is issued,  
linefeed generation will be turned on, and for ATL0, it  
will be off. Users may wish to have this option on if  
using a terminal program, but off if using a custom  
interface (as the extra characters transmitted will  
only serve to slow the vehicle polling down). The  
default setting is L1 (linefeeds on).  
Note that the length byte only represents the total  
number of data bytes following, and does not include  
itself. Also, if there was a data (checksum) error, the  
length byte will have its most significant bit set, so  
the user should always check first to see if the length  
is greater than 127. (The other 7 bits still provide a  
valid byte count if there is an error, so one need only  
ignore the msb, or subtract 128 from the value.)  
MA  
[ Monitor All messages ]  
Using this command places the ELM322 into a bus  
monitoring mode, in which it displays all messages  
as it sees them on the OBD bus. This continues  
indefinitely until stopped by activity on the RS232  
input. To stop the monitoring, one should send any  
single character then wait for the ELM322 to respond  
with a prompt character (‘>’). Waiting for the prompt  
is necessary as the response time is unpredictable,  
varying depending on what the IC was doing when  
interrupted. If for instance it is in the middle of  
printing a line, it will first complete the line then  
return to the command state, issuing the prompt  
character. If it was simply waiting for input, it would  
return immediately. The character which stops the  
monitoring will always be discarded, and will not  
affect subsequent commands.  
A ‘NO DATA’ response has no data bytes, but still  
sends a length byte with value ‘0’.  
R0 and R1  
[ Responses off (0) or on (1) ]  
These commands control the ELM322’s automatic  
display of responses. If responses have been turned  
off, the IC will not wait for anything to be returned  
from the vehicle after sending a request, and will  
return immediately to waiting for RS232 commands.  
This is useful if sending commands blindly when  
using the IC for a non-OBD network application, or  
simulating an ECU in a basic learning environment.  
The default is R1 (responses on).  
MR hh  
[ Monitor for Receiver hh ]  
SH xx yy zz  
[ Set the Header to xx yy zz ]  
This command also places the IC in a bus monitoring  
mode, displaying only messages that were sent to  
the hex address given by hh (messages which are  
found to have that value in their second byte). Any  
RS232 activity (single character) aborts the  
monitoring, as with the MA command.  
This command allows the user to control the values  
that are sent as the three header bytes in the  
message. The value of hex digits xx will be used for  
the first or priority/type byte, yy will be used for the  
second or target byte, and zz will be used for the  
third or source byte. These remain in effect until set  
again, or until restored to the default values with the  
AT D, or AT Z commands. The default header values  
are 68 6A F1, as required by the SAE J1979  
Diagnostic Test Modes (OBDII) standard.  
MT hh  
[ Monitor for Transmitter hh ]  
Another monitoring command, MT hh displays only  
messages sent by Transmitter address hh (given by  
ELM322DSE  
Elm Electronics – Circuits for the Hobbyist  
< http://www.elmelectronics.com/ >  