USE ULTRA37000TM FOR
ALL NEW DESIGNS
PALCE22V10
Output Current into Outputs (LOW)............................. 16 mA
DC Programming Voltage............................................. 12.5V
Latch-up Current.....................................................> 200 mA
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Static Discharge Voltage
(per MIL-STD-883, Method 3015) ............................>2001V
Operating Range
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Ambient
Supply Voltage to Ground Potential
(Pin 24 to Pin 12) ........................................... –0.5V to +7.0V
Range
Commercial
Industrial
Temperature
VCC
0°C to +75°C
–40°C to +85°C
–55°C to +125°C
5V ±5%
5V ±10%
5V ±10%
DC Voltage Applied to Outputs
in High-Z State ............................................... –0.5V to +7.0V
Military[1]
DC Input Voltage............................................ –0.5V to +7.0V
Electrical Characteristics Over the Operating Range[2]
Parameter
Description
Test Conditions
Min. Max. Unit
VOH
Output HIGH Voltage
VCC = Min.,
IN = VIH or VIL
IOH = –3.2 mA
Com’l
Mil/Ind
Com’l
Mil/Ind
2.4
V
V
I
OH = –2 mA
VOL
VIH
Output LOW Voltage
VCC = Min.,
VIN = VIH or VIL
IOL = 16 mA
0.5
V
I
OL = 12 mA
Input HIGH Level
Guaranteed Input Logical HIGH Voltage for All Inputs[3]
Guaranteed Input Logical LOW Voltage for All Inputs[3]
VSS < VIN < VCC, VCC = Max.
2.0
–0.5
–10
–40
V
V
[4]
VIL
Input LOW Level
0.8
10
40
IIX
Input Leakage Current
µA
µA
IOZ
ISC
ICC1
Output Leakage Current
Output Short Circuit Current VCC = Max., VOUT = 0.5V[5,6]
VCC = Max., VSS < VOUT < VCC
–30 –130 mA
90 mA
Standby Power Supply
Current
VCC = Max.,
IN = GND,
10, 15, 25 ns
5, 7.5 ns
15, 25 ns
10 ns
Com’l
V
130 mA
120 mA
120 mA
110 mA
140 mA
130 mA
130 mA
Outputs Open in Unprogrammed
Device
Mil/Ind
[6]
ICC2
Operating Power Supply
Current
VCC = Max., VIL = 0V, VIH = 3V,
Output Open, Device Programmed
as a 10-bit Counter,
10, 15, 25 ns
5, 7.5 ns
15, 25 ns
10 ns
Com’l
Com’l
Mil/Ind
Mil/Ind
f = 25 MHz
Capacitance[6]
Parameter
CIN
Description
Input Capacitance
Output Capacitance
Test Conditions
Min.
Max.
Unit
pF
VIN = 2.0V @ f = 1 MHz
VOUT = 2.0V @ f = 1 MHz
10
10
COUT
pF
Endurance Characteristics[6]
Parameter
Description
Minimum Reprogramming Cycles
Test Conditions
Normal Programming Conditions
Min.
Max.
Unit
N
100
Cycles
Notes:
1. T is the “instant on” case temperature.
A
2. See the last page of this specification for Group A subgroup testing information.
3. These are absolute values with respect to device ground. All overshoots due to system or tester noise are included.
4. V (Min.) is equal to –3.0V for pulse durations less than 20 ns.
IL
5. Not more than one output should be tested at a time. Duration of the short circuit should not be more than one second. V
caused by tester ground degradation.
= 0.5V has been chosen to avoid test problems
OUT
6. Tested initially and after any design or process changes that may affect these parameters.
Document #: 38-03027 Rev. *B
Page 4 of 13