MICROWAVE
A Division of Crystek Corporation
Harbour SS402 Cable
1.1 Trim Cable as shown.
Step 1
2.1 Slide clamp nut over cable as shown.
2.2 Insert cable into solder ferrule as shown then solder braids to ferrule where indicated.
2.3 Trim exposed cable dielectric flush with solder ferrule face.
2.4 Slide dielectric stop over cable center conductor against ferrule face and solder contact
flush against stop to dimension shown.
2.5 Slide forward insulator onto contact.
Step 2
NOTE: Distance from end of cable
center conductor to Ref. Pl. is 0.289
3.1 Insert cable/contact sub-assembly into connector until seated and tighten clamp nut to
25-35 in-lbs.
Step 3
Product Control:
Crystek Part Number:
Revision Level:
CS-SM-MHD
A
Release Date:
Responsible:
04-Jan-11
K. Piotrowicz
Page 2 of 2
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
CRYSTEK
CORPORATION
Fax: 239-561-1025 • www.crystek.com