1.1 Trim Cable as shown.
Step 1
Step 2
Step 3
2.1 Slide clamp nut over cable as shown.
2.2 Solder cable to solder ferrule with dielectric flush with face of ferrule.
2.3 Slide dielectric stop (Ø 0.200 OD) over cable center conductor and solder contact flush to
stop to dimension shown.
2.4 Slide forward insulator and dielectric bead (Ø 0.173 OD) onto contact.
NOTE: Distance from end of cable center
conductor to Ref. Pl. is 0.325 (Ref)
3.1 Insert cable/contact sub-assembly into connector until seated and tighten clamp nut to
25-35 in-lbs.