EVER BRIGHT OPTOELECTRONICS CORP.
EC04-1206QRC/E-AV
● Reliability Test
Classification
Test Item
Reference Standard
Test Conditions
Result
Operation Life MIL-STD-750D:1026 Connect with a power If=20mA
MIL-STD-883D:1005 Ta=Under room temperature
0/20
JIS-C-7021
:B-1
Test time=1,000hrs
Ta=+85℃±5℃
High
Temperature MIL-STD-202F:103B RH=90%-95%
0/20
High Humidity JIS-C-7021
:B-11 Test time=240hrs
Endurance
Test
Storage
High
Temperature
Storage
Low
High Ta=+100℃±5℃
MIL-STD-883:1008
JIS-C-7021
Test time=1,000hrs
:B-10
0/20
0/20
Low Ta=-40℃±5℃
Temperature JIS-C-7021
Storage
:B-11 Test time=1,000hrs
-35℃±5℃~+25℃~+85℃±5℃~+25℃
Temperature MIL-STD-202F:107D
Cycling MIL-STD-750D:1051 30min 5min
30min
5min
0/20
0/20
0/20
MIL-STD-883D:1010 Test Time=10cycle
JIS-C-7021 :A-2
Thermal Shock MIL-STD-202F:107D
-40℃±5℃ ~+85℃±5℃
Environmental
Test
MIL-STD-750D:1051 20min
MIL-STD-883D:1011 Test Time=10cycle
20min
Preheating:
140℃-160℃,within 2 minutes.
Operation heating:
Solder
Resistance
MIL-STD-202:201A
MIL-STD-750:2031
JIS-C-7021
:A-1
260℃(Max.), within 10seconds. (Max.)
● Judgment criteria of failure for the reliability
Measuring items
Forward voltage
Reverse current
Luminous intensity
Symbol
VF ( V)
Measuring conditions
IF=20mA
Judgement criteria for failure
Initial Level*1.1
IR(uA)
VR=5V
Over U*2
Iv ( mcd )
IF=20mA
Initial Level*0.7
Note: 1.U means the upper limit of specified characteristics.
2.Measurment shall be taken between 2 hours and after the test pieces have been returned to
normal ambient conditions after completion of each test.
Ver.1.0 Page 5 of 7
ONE THREE SIX ZERO ZERO TWO FIVE NINE SEVEN DOUBLE NINE,MR.CHEN