LAA120  
PERFORMANCE DATA*  
LAA120  
LAA120  
Typical On-Resistance Distribution  
(N=50 Ambient Temperature = 25°C)  
LAA120  
Typical LED Forward Voltage Drop  
(N=50 Ambient Temperature = 25°C)  
Typical Blocking Voltage Distribution  
(N=50 Ambient Temperature = 25°C)  
(Load Current = 170mADC; I = 5mADC)  
F
I
= 5mADC  
F
35  
30  
25  
20  
15  
10  
5
35  
30  
25  
20  
15  
10  
5
35  
30  
25  
20  
15  
10  
5
0
0
0
1.17  
1.19  
1.21  
1.23  
1.25  
6.5  
7.5  
8.5  
9.5  
10.5  
305 315 325 335 345 355 365  
LED Forward Voltage Drop (V)  
On-Resistance ()  
Blocking Voltage (V)  
LAA120  
LAA120  
LAA120  
Typical I for Switch Dropout  
F
Typical I for Switch Operation  
F
Typical Turn-On Time  
(N=50 Ambient Temperature = 25°C)  
(N=50 Ambient Temperature = 25°C)  
(N=50 Ambient Temperature = 25°C)  
(Load Current = 170mADC; I = 5mADC)  
F
)
(Load Current = 170mADC  
(Load Current = 170mADC)  
25  
20  
15  
10  
5
25  
25  
20  
15  
10  
5
20  
15  
10  
5
0
0
0
0.625 0.875 1.125 1.375 1.625 1.875 2.125  
0.15  
0.45 0.75 1.05 1.35 1.65 1.95  
0.3  
0.5  
0.7  
0.9  
1.1  
1.3  
1.5  
Turn-On (ms)  
LED Current (mA)  
LED Current (mA)  
LAA120  
LAA120  
Typical Turn-Off Time  
(N=50 Ambient Temperature = 25°C)  
(Load Current = 170mADC; I = 5mADC)  
LAA120  
Typical Leakage vs. Temperature  
(Measured across Pins 5 & 6 or 7 & 8)  
Typical Load Current vs. Temperature  
F
0.0250  
0.0200  
0.0150  
0.0100  
0.0050  
0
250  
200  
150  
100  
50  
25  
20  
15  
10  
5
20mA  
10mA  
5mA  
0
0
-40 -20  
0
20  
40  
60  
80 100 120  
-40  
-20  
0
20  
40  
60  
80  
100  
0.050 0.150 0.250 0.350 0.450 0.550 0.650  
Temperature (°C)  
Temperature (°C)  
Turn-Off (ms)  
LAA120  
LAA120  
LAA120  
Typical Blocking Voltage  
vs. Temperature  
Typical Turn-On vs. Temperature  
(Load Current = 170mADC)  
Typical Turn-Off vs. Temperature  
(Load Current = 170mADC)  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
0.700  
0.600  
0.500  
0.400  
0.300  
0.200  
0.100  
0
350  
345  
340  
335  
330  
325  
320  
315  
5mA  
10mA  
20mA  
5mA  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (°C)  
Temperature (°C)  
Temperature (°C)  
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact  
our application department.  
Rev. 7  
3
www.clare.com