Dyad®
FR2
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for extended period may degrade the device and effect
its reliability.
Ratings (@ 25˚ C)
Parameter
Min
Typ Max Units
Switching Voltage
FR2 - DYAD®
Switching Current
FR2 - DYAD®
Carry Current
FR2 - DYAD®
200 Volts
0.5 Amps
1.5 Amps
Switching Frequency
FR2 - DYAD®
500
Hz
Contact Resistance
FR2 - DYAD®
(See detailed specifications for more information.)
150 mΩ
Specifications
All parameters are at 25°C unless otherwise stated.
PARAMETER
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNITS
Contact Ratings
Operate ampere turns range
Release ampere turns range
Switching Voltage
Switching Current
Carry Current
Full Blade Tolerance = 1.5NI
Full Blade Tolerance = 1.5NI
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
1V, 10mA Signal Level
AT
AT
VL
IL
IC
-
-
-
-
-
10
5
-
-
-
-
-
-
-
-
-
-
-
-
30
30
200
500
1.5
10
-
-
-
-
NI
NI
VDC
mAmps
Amps
VA
x106 Ops
x106 Ops
x106Ops
x106 Ops
mΩ
Contact Rating
Life Expectancy
-
1000
500
2
2
80
Ru
10V, 10mA Low Level
50V, 100mA Telecom Load
100V, 100mA Rated Loads
50mV, 10mA(1)
-
-
-
Static Contact Resistance
Contact Material
CR
-
150
-
-
Switch Specifications
Insulation Resistance(2)
Capacitance
100V, 25°C, 40% RH
Across Open Contacts
Between Contacts
At nominal coil voltage,
10Hz Square Wave
Zener-Diode Suppression(3)
IR
-
-
109
-
250
-
1011
0.3
300
-
-
-
-
Ω
pF
VDC/Peak AC
ms
Dielectric Strength(5)
Operate Time,
including bounce
Release Time
TOP
0.5
TREL
-
-
0.2
ms
Environmental Ratings
Storage Temperature
Operating Temperature
Soldering Temperature
Vibration Resistance
Shock Resistance
Weight
TA
TO
-
G
S
-
-40
-40
-
-
-
-
-
-
-
-
-
+125
+125
+240
20
100
-
°C
°C
°C
Gs
Gs
5Hz - 200Hz
11 1ms, 1/2 Sine Wave
0.13
grams/unit
(1) Contact resistance measured with 4 terminal method, 1.1" between test leads
(2) >1012 Ω is available upon request
A 24V zener in series with a diode across the coil
(3)
(4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare Engineering for more details/recommendations
(5) 15 ampere turn minimum
Rev. 2
2
www.clare.com