CPC7695
1.6.4 TESTout Switches, SW5 and SW6
Parameter Test Conditions
Symbol
Minimum
Typical
Maximum
Unit
V
V
(differential) = T
to T
TESTOUT
SW5
LINE
(differential) = R
to R
TESTOUT
SW6
LINE
All-Off state.
+25° C,
V
V
(differential) = -320 V to gnd
(differential) = +260 V to -60 V
0.1
0.3
0.1
SW
SW
Off-State
Leakage Current
+85° C
V
V
(differential) = -330 V to gnd
I
-
1
μA
SW
SW
SW
(differential) = +260 V to -60 V
-40° C
V
V
(differential) = -310 V to gnd
SW
SW
(differential) = +250 V to -60 V
(on) = 10 mA, 40 mA
I
SW
+25° C
+85° C
-40° C
35
50
26
-
70
-
On Resistance
DC current limit
R
-
Ω
ON
V
(on) = 10 V
SW
+25° C
+85° C
-40° C
-
80
-
140
100
210
-
-
I
mA
A
SW
250
Test out switches on, all other switches
off. Apply 1 kV, 10x1000 μs pulse with
appropriate protection in place.
Dynamic current limit
(t ≤ 0.5 μs)
I
-
2.5
-
SW
V
(T
, T
SW5 TESTout LINE
)
V
(R
, R
SW6 TESTout LINE
)
Logic inputs = GND
Logic input to switch
output isolation
+25° C, V = 320 V
SW
0.1
0.3
0.1
+85° C, V = 330 V
SW
I
-
1
-
μA
SW
-40° C, V = 310 V
SW
100V Square Wave, 100Hz
PP
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
Transient Immunity
dV/dt
1500
2100
V/μs
8
PRELIMINARY
R00D